GRA SERIES GAS FRYERS - TROUBLESHOOTING
KLEENSCREEN FILTERING
SYSTEM
SYMPTOM
POSSIBLE CAUSES
Shortening not filtering, pump motor is
energized.
1. Filter screen plugged.
2. Clog in filter system lines.
NOTE:
If using solid shortening, when all filtered shortening
is returned to the fry tank and filter power switch is off, open
the filter drawer approximately one inch. Allow the remaining
shortening in the line to drain into the filter tank to prevent
possible clogging after the shortening cools and solidifies.
Close the filter drawer when complete.
3. Shortening below 300°F to thick.
4. R2 fill relay N.C. contacts are open.
5. Fill solenoid valve malfunction.
6. Interconnecting wiring malfunction.
7. Pump is inoperative.
Shortening not discarding, pump motor
energized.
1. Filter screen plugged.
2. Clog in filter system lines.
NOTE:
If using solid shortening, when all filtered shortening
is returned to the fry tank and filter power switch is off, open
the filter drawer approximately one inch. Allow the remaining
shortening in the line to drain into the filter tank to prevent
possible clogging after the shortening cools and solidifies.
Close the filter drawer when complete.
3. Shortening below 300°F to thick.
4. Discard valve switch malfunction (N.O. contacts not
closing to energize R2 fill relay coil).
5. R2 fill relay malfunction (contacts remain closed).
NOTE:
The fill solenoid valve should not be energized
during discard operation so that shortening will flow thru
manual discard valve only.
6. Discard valve mechanical malfunction.
7. Discard hose connection not fully engaged.
8. Pump is inoperative.
Pump motor is not energized to circulate
shortening thru filtering system.
1. Filter switch on cooking controls not turned on.
2. Pump needs reset. (Reset button located on pump)
3. R1 pump motor relay malfunction.
4. Cooking control malfunction.
5. Interconnecting wiring malfunction.
6. Pump motor inoperative.
Pump motor is not energized to discard
shortening.
1. Filter switch on cooking controls not turned on.
2. Pump needs reset. (Reset button located on pump)
3. Discard handle (yellow) not extended.
4. R1 pump motor relay malfunction.
5. Cooking control malfunction.
6. Interconnecting wiring malfunction.
7. Pump motor inoperative.
F25377 (March 2010)
Printed in U.S.A.
Содержание 136647
Страница 21: ...GRA SERIES GAS FRYERS ELECTRICAL OPERATION POWER SUPPLY BOX COMPONENTS F25377 March 2010 Page 21 of 36 ...
Страница 27: ...GRA SERIES GAS FRYERS ELECTRICAL OPERATION F25377 March 2010 Page 27 of 36 ...
Страница 29: ...GRA SERIES GAS FRYERS ELECTRICAL OPERATION F25377 March 2010 Page 29 of 36 ...
Страница 30: ...GRA SERIES GAS FRYERS ELECTRICAL OPERATION Frymate Dump Station F25377 March 2010 Page 30 of 36 ...