The red led in the lower left corner in
Figure 6 indicates the detected motion. By
pressing the red led the interrupt is cleared
by reading the INT_STATUS register.
The INT_STATUS register contains the
information of the interrupt cause. In Figure
6 Y- and Z-axis acceleration triggered the
motion detector in previous time.
The pull down menu for different displays
is disabled when free fall or motion
detector mode is activated.
Figure 6. Scroll display with detected motion.
BUBBLE LEVEL
, two displays that show
tilt angle, see Figure 7. Angle calculation is
performed in GUI, not in SCA3000 sensor.
SCA3000 sensor averaging can be
enabled / disabled.
Figure 7. Bubble level display.