www.vtiinstruments.com
EX10xxA Function Calls
171
vtex10xxA_get_lan_event_source_state
F
UNCTION
P
ROTOTYPE
ViStatus vtex10xxA_get_lan_event_source_state(ViSession
vi
,ViPInt32
arm_state
,ViPInt32
trig_state
);
F
UNCTION
P
ARAMETERS
vi
= contains a session handle to the instrument. This handle is obtained by the function and remains valid until the
session is closed.
arm_state
= returns an integer output value representing the 8-bit value of the port. Within the 8-bit field, the MSB
corresponds to VTB channel 7 and the LSB corresponds to VTB channel 0. Valid return values are: 0 to 255.
trig_state
= returns an integer output value representing the 8-bit value of the port. Within the 8-bit filed, the MSB
corresponds to VTB channel 7 and the LSB corresponds to VTB channel 0. Valid return values are: 0 to 255.
D
ATA
I
TEM
R
ESET
V
ALUE
Not applicable to this function.
D
ESCRIPTION
This function queries and returns the current arm and trigger state of the LAN events.
E
XAMPLE