VTech DS6673 Скачать руководство пользователя страница 10

6

The 

Bluetooth

®

 word mark and logos are owned by Bluetooth SIG, Inc. and any use of such 

marks by VTech Holdings Limited is under license. VTech Holdings Limited is a member of 

Bluetooth SIG, Inc. Other trademarks and trade names are those of their respective owners.

VTECH TELECOMMUNICATIONS LTD.

A member of THE VTECH GROUP OF COMPANIES.

Distributed in the U.S.A. by VTech Communications, Inc., Beaverton, Oregon 7008.

Distributed in Canada by VTech Technologies Canada Ltd., Richmond, B.C. V6W L5.

VTech is the registered trademark of VTech Holdings Limited.

Copyright © 03 for VTECH TELECOMMUNICATIONS LTD.

All rights reserved. Printed in China.

-00668-00-00

To ensure safety of users, the FCC has established criteria for the amount of radio frequency energy that can 

be safely absorbed by a user or bystander according to the intended usage of the product. This product has 

been tested and found to comply with the FCC criteria. The handset may be safely held against the ear of the 

user. The telephone base shall be installed and used such that parts of the user’s body other than the hands 

are maintained at a distance of approximately 0 cm (8 inches) or more.
This Class B digital apparatus complies with Canadian ICES-003.

FCC Part 68 and ACTA

This equipment complies with Part 68 of the FCC rules and with technical requirements adopted by the 

Administrative Council for Terminal Attachments (ACTA). The label on the back or bottom of this equipment 

contains, among other things, a product identifier in the format US:AAAEQ##TXXXX. This identifier must be 

provided to your telephone service provider upon request.
The plug and jack used to connect this equipment to premises wiring and the telephone network must comply 

with applicable Part 68 rules and technical requirements adopted by ACTA. A compliant telephone cord and 

modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is 

also compliant. An RJ jack should normally be used for connecting to a single line and an RJ4 jack for two 

lines. See the installation instructions in the user’s manual.
The Ringer Equivalence Number (REN) is used to determine how many devices you may connect to your 

telephone line and still have them ring when you are called. The REN for this product is encoded as the 6th 

and 7th characters following the US: in the product identifier (e.g., if ## is 03, the REN is 0.3). In most, but 

not all areas, the sum of all RENs should be five (5.0) or less. For more information, please contact your 

telephone service provider.
This equipment may not be used with Party Lines. If you have specially wired alarm dialing equipment 

connected to your telephone line, ensure the connection of this equipment does not disable your alarm 

equipment. If you have questions about what will disable alarm equipment, consult your telephone service 

provider or a qualified installer.

If this equipment is malfunctioning, it must be unplugged from the modular jack until the problem has been 

corrected. Repairs to this telephone equipment can only be made by the manufacturer or its authorized 

agents. For repair procedures, follow the instructions outlined under the 

Limited warranty

.

If this equipment is causing harm to the telephone network, the telephone service provider may temporarily 

discontinue your telephone service. The telephone service provider is required to notify you before 

interrupting service. If advance notice is not practical, you will be notified as soon as possible. You will be 

given the opportunity to correct the problem and the telephone service provider is required to inform you of 

your right to file a complaint with the FCC. Your telephone service provider may make changes in its facilities, 

equipment, operation, or procedures that could affect the proper functioning of this product. The telephone 

service provider is required to notify you if such changes are planned.
If this product is equipped with a corded or cordless handset, it is hearing aid compatible.
If this product has memory dialing locations, you may choose to store emergency telephone numbers  

(e.g., police, fire, medical) in these locations. If you do store or test emergency numbers, please:
Remain on the line and briefly explain the reason for the call before hanging up.

Perform such activities in off-peak hours, such as early morning or late evening.

Industry Canada

Operation is subject to the following two conditions: () this device may not cause harmful interference, and 

() this device must accept any interference, including interference that may cause undesired operation.

The term ‘’IC:‘’ before the certification/registration number only signifies that the Industry Canada technical 

specifications were met.

The Ringer Equivalence Number (REN) for this terminal equipment is .0. The REN is an indication of 

the maximum number of devices allowed to be connected to a telephone interface. The termination on an 

interface may consist of any combination of devices subject only to the requirement that the sum of the RENs 

of all the devices does not exceed five.
This product meets the applicable Industry Canada technical specifications.

Technical specifications

Frequency control 

Crystal controlled PLL synthesizer

Transmit frequency

DECT frequency: .536-8.448 MHz
Bluetooth frequency: 40.000-480.000 MHz

Channels

DECT: 5
Bluetooth: 7

Nominal effective range

Maximum power allowed by FCC and IC. Actual operating 

range may vary according to environment conditions at the  

time of use.

Power requirements

Handset: .4V Ni-MH battery
Telephone base:

 Output #1: 

6V DC @ 450mA;; 

                            Output #2: 

6V DC @ 300mA

Charger: 6V AC @ 300mA

Memory

Home phonebook: 

00 memory locations; up to 30 digits and 5 characters
Cell phonebooks: 

000 memory locations (each); up to 30 digits and 5 characters
Caller ID log:  

50 memory locations; up to 4 digits and 5 characters

Содержание DS6673

Страница 1: ...ime sync Set to synchronize the time in the caller ID log On Off Dial mode Set the telephone to be touch tone or pulse dialing Touch tone Pulse Use the Clr voicemail feature when the telephone indicat...

Страница 2: ...wer a home cell call Press HOME CELL 1 CELL 2 or any dialing key Press on the headset End a home cell call Press OFF on the handset or put the handset to the telephone base or charger Press on the hea...

Страница 3: ...of one or multiple handsets To start a PTT communication Press PUSH TO TALK when the phone is not in use Scroll to a desired handset or Group Press SELECT Only one handset can talk at a time Press an...

Страница 4: ...at have not been reviewed in the caller ID log If you want to erase the missed call indicator press and hold CANCEL on the idle handset To review and dial a number in the caller ID log Press CID when...

Страница 5: ...phone Press 5 when done Answering system operation Turn the answering system on or off The answering system must be turned on to answer and record messages Press ANS ON OFF on the telephone base to tu...

Страница 6: ...base Make sure you have cellular coverage Make sure your cell phone is compatible with your DS6673 Check the Bluetooth compatibility list at www vtechcanada com Make sure the Bluetooth function of you...

Страница 7: ...be blocked by placing the product on a soft surface such as a bed sofa or rug This product should never be placed near or over a radiator or heat register This product should not be placed in any are...

Страница 8: ...e some limitations Telephone calls are transmitted between the telephone base and the cordless handset by radio waves so there is a possibility that the cordless telephone conversations could be inter...

Страница 9: ...oduct failure is not covered by this limited warranty or proof of purchase does not meet the terms of this limited warranty VTech will notify you and will request that you authorize the cost of repair...

Страница 10: ...ent consult your telephone service provider or a qualified installer If this equipment is malfunctioning it must be unplugged from the modular jack until the problem has been corrected Repairs to this...

Отзывы: