18
MULTICONDUCTOR CONNECTION BOX OF FILTRATION UNITS (with electric heater)
cable 2x1,0mm
2
to spotlight
transformer
spotlight pneumatic
switch
brown
cable 7x2,5mm
2
to electric control panel
cable 2x1,0mm
2
to electric heater
blue
brown
yellow-green
wire 2,5mm
2
to ground
yellow-green
blue
5
6
2
1
1
3
cable 4x2,5mm
2
to pump 20/50m
3
(cable 3x1,5mm
2
to pump 15, 25m
3
)
black (only for VUB20/50)
ELECTRICAL CONNECTION SCHEME OF HEAT EXCHANGER
in universal blocks VU
В
15, VU
В
25 and VUB20/50
Make connection of mounted equipment and connect with electrical control panel of filtration unit according
enclosed diagram.
electric control panel
of filtration unit
thermal protection
switch
switch
heat exchanger
circulation pump
electromagnetic
valve
phase
(from electronic
thermostat)
N