Page 3/4 

4

 

LED-Display 

4.1

 

internal green LED 

OFF: 

Switch is OFF 

ON: 

Switch is ON 

Blinking: 

Magnet near Sensor, switch status is kept on previous state 

 

-or- 

 

Fault, no servo signal for more than 2.5 seconds, switch is "OFF" 

Flickering: 

Programming mode (switch is "ON") 

Single-Pulse:  Mode1 „ON“ 
Double-Pulse:  Mode2 „PWM-Mode“ 

4.2

 

external blue LED 

OFF: 

Load is switched "OFF", no connection to the load battery 

ON: 

Load is switched "ON", power from load battery 

5

 

Technical data 

Servo input 

3,0 … max 15V 

Switching voltage 

3,0 … max 20V (3…13 Cells NiCd/NiMh, 1 to 4 Cells LiPo/LiFe) 

Switch current 

max 20 A 

Power consumption 
(control part, powered by the RX) 

ON:  about 13 mA 

OFF:  about. 4 mA 

Power consumption 
(switching part, powered by the 
external battery) 

ON:  about 8 mA/ 2mA    with / without external blue LED 

OFF:  ~

0 mA

   (max 0,001 mA) 

Mode 2, Pulsefrequency 

~510 Hz 

Size 

30 x 9 x 8 mm (PCB) 

Weight 

6 g   (incl. cable) 

Connectors 

RX cable (0,14 mm²) 

red: 

Battery-positive:  15cm Silicone cable (1,0 mm²) 

black: 

Battery-negative: 15cm Silicone cable (0,25 mm²) 

yellow/red: 

switched line

:  15cm Silicone cable (1,0 mm²) 

2-pin socket for the external blue LED 

The "ON" range can be programmed completely free. 

Содержание Electronic switch 20A (opto)

Страница 1: ...via an optocoupler from the load side You can use a separate power source for the load The electronic switch opto switches the positive line The electronic switch is connected to a servo terminal on the receiver It can be easily programmed with a magnet The operating mode switch state programming and malfunctions are signalled with the integrated green LED The optional external blue LED can be con...

Страница 2: ...ting the switch threshold first the operation mode is shown with the blinking LED by moving the proportional control stick knob on the radio for this channel Remark If you change the operation mode the previously changed switch threshold will NOT be stored 3 3 Changing the pulse width in Mode 2 If you have activated Mode 2 in the previous step and the magnet is still near the magnet sensor you can...

Страница 3: ...hnical data Servo input 3 0 max 15V Switching voltage 3 0 max 20V 3 13 Cells NiCd NiMh 1 to 4 Cells LiPo LiFe Switch current max 20 A Power consumption control part powered by the RX ON about 13 mA OFF about 4 mA Power consumption switching part powered by the external battery ON about 8 mA 2mA with without external blue LED OFF 0 mA max 0 001 mA Mode 2 Pulsefrequency 510 Hz Size 30 x 9 x 8 mm PCB...

Страница 4: ...striction of Hazardous Substances RoHS The presumption of conformity is taken by applying the following harmonized standards EN60065 Audio video and similar electronic aparatus Safety requirements EN60332 Tests on electric and optical fibre cables under fire conditions EN60950 Information technology equipment Safety EN61000 6 1 Electromagnetic compatibility EMC EN61000 6 3 EN55022 Information tech...

Отзывы: