background image

 

VS Security Products LTD

 

ZZ009174, ZZ009177

 

Page 6 of 15

 

 

 

 

 

NOTE: 

The degaussing coils are powered as part of a tuned resonant circuit. This allows quite high circulating currents to be 

generated  within  the  degaussing  coils,  with  minimal  current  consumption  from  the  mains  voltage  supply.  However,  this 

technique requires that the waveform of the supply voltage contains minimal harmonic distortion. A distorted waveform will 

result in an increase in current consumption.

 

 

 

 

The typical current consumption figures provided in this manual are when powered from a supply with minimal distortion. Any 

increase  in  current  consumption  due  to  a  distorted  waveform  will  have  minimal  effect  on  the  degausser  performance, 

however, excessive current consumption should be avoided for obvious reasons. In the event of unexplained high currents, 

please consult your supplier

.

 

 

 

 

 

SECTION 4: OPERATION

 

 

 

 

 

WARNING!

 

 

 

strong magnetic fields are generated. remove watches before use. Ensure that the fan 

 

 

operates correctly during use. (After initial warm up period). operating periods in excess of 

 

 

specified duration will result in exterior surfaces becoming very hot.

 

 

 

 

 

4.1 Turning on the V91 MAX

 

 

 

The V91 MAX degausser has been designed for simplicity of operation in that it consists basically of a flat bed over which the 

magnetic media is passed. Control is via a single on/off switch and indicator. 

 

 

 

The illuminating on/off power switch is of the latching push button type which energises the degaussing coil. On units with the 

key switch option fitted, the power switch will illuminate as normal when switched on, but will also require the key switch to be 

turned clockwise for correct operation.

 

 

 

NOTE:

  Where  a  security  key  switch  is  fitted,  the  degaussing  coil  must  only  be  energised  and  de

-

energised  by  using  the 

power switch, i.e. use the RED BUTTON to switch power ON/OFF, 

NOT

 the key switch.

 

 

 

4.2 Erasure of Hard Drives

 

 

 

 

Because of the different types and manufactures specifications of PC hard disk units, VS Security Products only recommends 

the erasure of hard disk units as a security precaution for the following:

 

 

a.

 

Erasure of data from a faulty disk pack before being sent for service/repair.

 

b.

 

Erasure of data from disk packs before disposal of computer equipment.

 

 

 

 

NOTE: 

VS Security Products cannot guarantee that a drive will be operational after degaussing.

 

 

 

 

Method

 

 

 

 

 

The hard disk pack can be erased as a whole unit and there is no need to remove the disks.

 

 

1.

 

Place the hard disk drive on V91 MAX

s surface, slightly off

-

centre as shown in Fig. 1 (Note –

 

Relative position of drive 

PCB)  and hold  down.  The  hard  disk

s  PCB  board should be  facing  upwards  for the  first two  operations  then  facing 

down for the 3

rd

 & 4

th

 operations. 

 

2.

 

Switch the degausser ON for 3

-

5 seconds and then switch OFF. 

 

 

 

NOTE: 

The magnetic field might cause the hard disk to vibrate. This is quite normal.

 

 

3.

 

Rotate the hard disk through 90 degrees (Fig. 2). Switch ON the degausser for 3

-

5 seconds and then switch OFF.

 

4.

 

Flip the hard disk over (PCB facing down) (Fig. 3). Switch ON the degausser for 3

-

5 seconds and then switch OFF.

 

5.

 

Rotate the hard disk through 90 degrees (Fig. 4). Switch ON the degausser for 3

-

5 seconds and then switch OFF.

 

 

 

The hard disk is now erased.

 

 

 

 

 

 

Содержание V91 MAX

Страница 1: ...ZZ009174 ZZ009177 Rev 12 ...

Страница 2: ...metres 6 Feet from the degausser IMPORTANT the power on off switch used on this equipment is not an isolating switch it is recommended that this equipment should be operated from a separate switched isolator which should be located close to the unit and within reach of the operator COPYRIGHT This document is the property of VS Security Products Ltd and it may not be reproduced copied or exhibited ...

Страница 3: ... S SECTION PAGE 1 Specification 4 2 Introduction to the V91 MAX Degausser 5 3 Installation 5 4 Operation 6 5 Indicators Features 8 6 Maintenance Service 9 7 Tables 10 8 Parts List 11 This document refers to V91 MAX part no s ZZ009174 208 220v 60Hz ZZ009177 220 240v 50Hz ...

Страница 4: ...DUTY CYCLE 20 Dependant on ambient temperature RUN TIME 2 minutes ERASURE TIME 20 seconds typical OPERATING VOLTAGE ZZ009177 220 240v 50Hz ZZ009174 208 220v 60Hz CURRENT 10 amps typical 220 240v 50Hz 12 amps typical 208 220v 60Hz CIRCUIT BREAKER ZZ009177 12A 50Hz ZZ009174 15A 60Hz SECURITY KEY SWITCH Standard MOUNTING Free standing table top DIMENSIONS 19 x 16 5 x 6 48cm x 42cm x 15cm DIMENSIONS P...

Страница 5: ... MAX eraser The V91 MAX is capable of removing data from PC hard drives in less than 20 seconds Although in most cases this will render the hard drive inoperative the cost of a replacement hard drive cannot be compared to the cost to a company if sensitive information can be read by a third party DLT Anyone replacing their existing DLT drive with the new DLT1 drive should be aware that their exist...

Страница 6: ... switch option fitted the power switch will illuminate as normal when switched on but will also require the key switch to be turned clockwise for correct operation NOTE Where a security key switch is fitted the degaussing coil must only be energised and de energised by using the power switch i e use the RED BUTTON to switch power ON OFF NOT the key switch 4 2 Erasure of Hard Drives Because of the ...

Страница 7: ...be turned through 90 degrees and a second pass made the media must be turned over and the process repeated making a total of four passes to ensure complete erasure 4 4 Erasure of Reels and Pancakes The media in reel or pancake form to be erased should be brought slowly towards the top surface The media should be placed on the surface and rotated slowly and evenly taking approximately five seconds ...

Страница 8: ...d by the degaussing magnetic field and is considered more reliable being a red flashing LED 5 3 Overheat Protection The high energy field developed by the V91 MAX necessitates the generation of a considerable amount of heat The de gausser coil is monitored for excessively high temperatures and should this condition occur its operation will be inhibited until the coil has cooled sufficiently 5 4 Co...

Страница 9: ...protected and does not require servicing However in the event of failure the fan may easily be replaced from the rear of the degausser 6 4 Internal Components Most of the internal components are replaceable i e the solid state relay toroidal transformer and the thermal switches mounted on the degausser coil However the tuning capacitors and the degaussing coil are not spared items and if found to ...

Страница 10: ...l L1 and or tuning capacitors C1 C4 User source Inside centre and left hand side Power lamp Fails to illuminate Loss of mains supply Tripped circuit breaker Faulty switch Faulty neon User source Rear panel Front panel Front panel Degauss lamp Fails to illuminate flashes Extensive use of degausser caused overheating Allow unit to cool Not a fault Faulty Neon Faulty solid state relay R1 Faulty therm...

Страница 11: ... Relay SH100150 1 Relay Cover SW3 SP100002 1 Temperature Sensor SW2 SW100016 2 Thermal Switch CB1 SW100017 1 15A Circuit Breaker SW1 SW100123 1 Red lens SW1 SW100125 1 Switch Body SW1 SW100126 1 Switch Contact Block IND1 SW100121 1 Yellow lens IND1 SW100124 1 Indicator IND1 SW100127 1 Dummy Socket TX1 TX100027 1 Auto Toroid Transformer MP003065 1 Fan Plate SW4 SW100070 1 Security Key Switch IND2 O...

Страница 12: ...elay SH100150 1 Relay Cover SW3 SP100002 1 Temperature Sensor SW2 SW100016 2 Thermal Switch CB1 SW100066 1 12A Circuit Breaker SW1 SW100123 1 Red lens SW1 SW100125 1 Switch Body SW1 SW100126 1 Switch Contact Block IND1 SW100121 1 Yellow lens IND1 SW100124 1 Indicator IND1 SW100127 1 Dummy Socket TX1 MP002325 1 Filter XX001118 1 Fan Plate SW4 SW100070 1 Security Key Switch IND2 OI100017 1 Flashing ...

Страница 13: ...VS Security Products LTD ZZ009174 ZZ009177 Page 13 of 15 8 3 Circuit Diagram ZZ009177 50Hz ...

Страница 14: ...VS Security Products LTD ZZ009174 ZZ009177 Page 14 of 15 8 4 Circuit Diagram ZZ009174 60Hz ...

Страница 15: ...VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES Unit 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot California GU12 4QP 95667 UK USA ...

Отзывы: