VS DATAGONE Скачать руководство пользователя страница 5

________________________________________________________________________________ 

VS SECURITY PRODUCTS

 

ZZ001203 - ZZ001204 

Page 5 of 13 

Operating Instructions 

2. 

INTRODUCTION TO THE DATAGONE DEGAUSSER 

 

The 

DATAGONE 

is a high energy, hard drive eraser designed to offer complete and 

secure erasure of magnetic media including perpendicular recording hard drives. The 
DATAGONE  is  also  capable  of  erasing  data  storage  media  including  DLT,  LTO, 
8mm, DDS and more. 
 

Performance 
 

The DATAGONE generates one of the strongest erasure fields of any degausser on 
the  market.  Where  security  is  of  the  utmost  importance,  users  can  quickly  sanitise 
their media without the need for disassembly. 
 

Operation 
 

The  DATAGONE  is  a bench mounted, chamber degausser, making operation safe, 
effective and simple for anyone. Operators simply “post” the media into the aperture 
on  one  side  of  the  unit  and  wait for  the  media  to  exit  the  aperture  on the opposing 
side  of  the  degausser.  The  powerful  degaussing  magnetic  field  is  automatically 
activated  by  internal  sensors  detecting  the  presence  of  media  which,  when  the 
degauss  field  has  decayed,  is  then  released  to  exit  the  degausser.  The  entire 
process  takes  just  8  seconds.  The  processor  controlled  DATAGONE  continuously 
monitors the operation ensuring that the erasure cycle is completed. The operator is 
immediately  alerted  to  any  interruptions  in  the  erasure  cycle  on  the  LCD  control 
panel. 
 
After  degaussing  hard  drives  should  not  be  reused  as  they  are  stressed  in  the 
erasure process and parts can be damaged. 
 
Backup tapes cannot be used after erasure as the control track may be erased in the 
degaussing process

Содержание DATAGONE

Страница 1: ...TECHNICAL MANUAL Operating and Maintenance Instructions for DATAGONE HARD DRIVE DEGAUSSER ZZ001203 ZZ001204...

Страница 2: ...AUSSER IMPORTANT THE POWER ON OFF SWITCH USED ON THIS EQUIPMENT IS NOT AN ISOLATING SWITCH IT IS RECOMMENDED THAT THIS EQUIPMENT SHOULD BE OPERATED FROM A SEPARATE SWITCHED ISOLATOR COPYRIGHT This doc...

Страница 3: ...Instructions C O N T E N T S SECTION PAGE List of Contents 3 1 Specification 4 2 Introduction 5 3 Installation 6 4 Control Panel 7 5 Using the Control Panel 7 6 Operation Guide 8 7 Error Messages 9 8...

Страница 4: ...t temperature CYCLE TIME 8 seconds typical OPERATING VOLTAGE 230v 50Hz or 115v 60Hz unit dependant CURRENT 5 amps typical 230 V 50 Hz 9 amps typical 115 V 60 Hz TEMPERATURE 5 C 41 F to 40 C 104 F HUMI...

Страница 5: ...chamber degausser making operation safe effective and simple for anyone Operators simply post the media into the aperture on one side of the unit and wait for the media to exit the aperture on the op...

Страница 6: ...mounted on a pallet Unpack the degausser carefully by disassembling the packing case and inspect it for signs of physical damage If damage is apparent a claim should be filed with the carrier immedia...

Страница 7: ...r and will illuminate whenever power is applied The power switch is part of the IEC power connector module mounted on the rear panel 5 3 Reset Button Once you have placed media in the unit the degauss...

Страница 8: ...is this end that should be leading when inserted into the degausser This ensures the hard drive is perfectly positioned in the degauss field 4 Once the degauss cycle is complete the hard drive will em...

Страница 9: ...on again using the power switch on the rear of the unit 7 1 START UP ERROR EXIT SENSOR TRUE If this message is displayed the Input optical sensor may be contaminated with dust or dirt To resolve this...

Страница 10: ...auss chute to detect the media when it enters the unit If the media is dusty or the unit is used in a dusty environment the sensor can become contaminated and not see the media This will result in the...

Страница 11: ...ove and clean the sensor The other half of the sensor is on the side of the chute directly opposite the one shown in the Photograph above and should be cleaned in the same way 8 3 Cleaning the Degauss...

Страница 12: ...n the rear of the unit this can be manually reset by the user If the unit fails in any way the user should verify the condition of the circuit breaker prior to contacting support 9 SAFETY RECOMMENDATI...

Страница 13: ...f 13 Operating Instructions VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot CA 95667 Hampshire GU12 4QP USA UK Tel 44 0 1252 33357...

Отзывы: