TECHNICAL
MANUAL
Operating and Maintenance
Instructions
for
DATAGONE
HARD DRIVE DEGAUSSER
ZZ001203 / ZZ001204
Страница 1: ...TECHNICAL MANUAL Operating and Maintenance Instructions for DATAGONE HARD DRIVE DEGAUSSER ZZ001203 ZZ001204...
Страница 2: ...AUSSER IMPORTANT THE POWER ON OFF SWITCH USED ON THIS EQUIPMENT IS NOT AN ISOLATING SWITCH IT IS RECOMMENDED THAT THIS EQUIPMENT SHOULD BE OPERATED FROM A SEPARATE SWITCHED ISOLATOR COPYRIGHT This doc...
Страница 3: ...Instructions C O N T E N T S SECTION PAGE List of Contents 3 1 Specification 4 2 Introduction 5 3 Installation 6 4 Control Panel 7 5 Using the Control Panel 7 6 Operation Guide 8 7 Error Messages 9 8...
Страница 4: ...t temperature CYCLE TIME 8 seconds typical OPERATING VOLTAGE 230v 50Hz or 115v 60Hz unit dependant CURRENT 5 amps typical 230 V 50 Hz 9 amps typical 115 V 60 Hz TEMPERATURE 5 C 41 F to 40 C 104 F HUMI...
Страница 5: ...chamber degausser making operation safe effective and simple for anyone Operators simply post the media into the aperture on one side of the unit and wait for the media to exit the aperture on the op...
Страница 6: ...mounted on a pallet Unpack the degausser carefully by disassembling the packing case and inspect it for signs of physical damage If damage is apparent a claim should be filed with the carrier immedia...
Страница 7: ...r and will illuminate whenever power is applied The power switch is part of the IEC power connector module mounted on the rear panel 5 3 Reset Button Once you have placed media in the unit the degauss...
Страница 8: ...is this end that should be leading when inserted into the degausser This ensures the hard drive is perfectly positioned in the degauss field 4 Once the degauss cycle is complete the hard drive will em...
Страница 9: ...on again using the power switch on the rear of the unit 7 1 START UP ERROR EXIT SENSOR TRUE If this message is displayed the Input optical sensor may be contaminated with dust or dirt To resolve this...
Страница 10: ...auss chute to detect the media when it enters the unit If the media is dusty or the unit is used in a dusty environment the sensor can become contaminated and not see the media This will result in the...
Страница 11: ...ove and clean the sensor The other half of the sensor is on the side of the chute directly opposite the one shown in the Photograph above and should be cleaned in the same way 8 3 Cleaning the Degauss...
Страница 12: ...n the rear of the unit this can be manually reset by the user If the unit fails in any way the user should verify the condition of the circuit breaker prior to contacting support 9 SAFETY RECOMMENDATI...
Страница 13: ...f 13 Operating Instructions VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot CA 95667 Hampshire GU12 4QP USA UK Tel 44 0 1252 33357...