7
225°
3
4
(9)
(10)
(7)
(7)
(6)
(6)
(4)
(4)
(5)
(8)
Adjusting rotation inhibition (Fig. 3)
The radius of rotation is factory-set to 180°. By removing
the two screws
(4)
and inserting one of the two screws in
the new position
(5)
it is possible to increase the radius of
rotation to 225°.
Important!
Keep the second screw in case you need
to change the setting back again later.
The table can then be rotated and set on its feet by two
people.
Fixing the supporting post to the floor
(Fig. 4)
To ensure that the upright table is stable, it is necessary to
fix the supporting post to the floor. First remove the two
cover pieces
(6)
. To do this, remove the two screws
(7)
Then
lift the cover pieces gently and pull them from the post.
Align the base plate
(8)
and screw firmly to the floor
through all the drill holes using suitable screws.
Caution!
Make sure that the screws are tightened se-
curely in order to ensure that the table remains stable.
Tighten each screw to a minimum force of 2000 N.
Replace the cover pieces
(6)
and screw them in place.
You can now rotate the table around the post by180° or
225°. To do this, you must release the brakes
(9).
Caution!
After rotating the table, lock the castors
(10)
win place again.
Содержание 01442-001