Playing Records 

 

Before playing a record, make sure that all of the tonearm screws 

are tight.  

 

General Use 

 

Allow at least 20 hours of break-in time.  

 

If you notice hum in the system, remove your interconnects and 

replace them with very cheap, standard VCR interconnects. These 

are well shielded and should eliminate the hum. If the hum goes 

away, get quality, well shielded interconnects. 

 
 

VPI Industries, Inc. Limited Warranty 

VPI Industries, Inc. (VPI) warrants this unit against defects in materials 

and/or workmanship for five (5) years from the date of purchase by the 

original retail purchaser. VPI’s sole obligation under this warranty is limited 

to the repair or replacement, at VPI’s option, of any part(s) found to be 

defective. VPI’s obligation to repair or replace defective parts is the 

purchaser’s sole and exclusive remedy, and VPI shall not be liable for any 

direct or indirect injury and/or property damage arising out of the use of the 

product or defect in or failure of the product.  

This warranty does not extend to any unit whose serial number has been 

defaced or altered. Any product that VPI determines causes a defect or 

malfunction due to incorrect installation, modification, misuse, or servicing 

by the purchaser, or service technician not authorized by VPI to perform 

such service will not be warranted. This warranty does not cover trivial or 

cosmetic defects that do not impair the unit’s normal function. 

VPI reserves the right to make changes in this product without assuming any 

obligation to install such change in any product previously manufactured. 

This warranty to repair or replace defective parts is in lieu of all other 

express or implied warranties of merchantability or fitness for a particular 

purpose. There are not warranties that extend beyond the description 

herein. 

Some states do not allow exclusion of implied warranties or limitation of 

incidental or consequential damages, so the above exclusion or limitations 

may not apply to you. This warranty gives you specific legal rights, and you 

may also have other rights that vary from state to state.  

 
 

Содержание JMW-9

Страница 1: ...JMW 9 MEMORIAL TONEARM Setup and Instruction Manual VPI Industries Inc 77 Cliffwood Ave 3B Cliffwood NJ 07721 phone 732 583 6895 fax 732 946 8578 http www vpiindustries com ...

Страница 2: ...he hardware supplied with the tonearm Be sure to use washers under the screw heads The tonearm wires are color coded as follows Red right hot Green right ground White left hot Blue left ground If your phono section inverts phase the hot color becomes the ground color Using tweezers or fine tipped pliers grip the center of the red wire s connector not the wire itself and push it onto the cartridge ...

Страница 3: ...he grid Set the counterweight for enough downward force to keep the stylus from moving when resting on the jig Look down at the cartridge and align it between the lines of the grid Be careful to align the cartridge and not the tonearm headshell Adjust the cartridge mounting screws as needed until the cartridge is centered between the grid lines and the stylus is resting on the dot of the grid The ...

Страница 4: ... we tried sounded better with its mechanical anti skating disabled and the tracking force very slightly increased VPI has a unique solution to anti skating the coiled wire of the JMW Memorial Tonearm acts as a spring and pushes the arm back without affecting the sound quality You now have the option of installing a mechanical anti skate for those that want it Adjust the counterweight so there is n...

Страница 5: ...Follow the gauge instructions and set the tracking force according to the cartridge manufacturer s recommendation We recommend always going to the high side of tracking force High frequency vibrations on a light tracking cartridge can cause more damage to the grooves of a record than running a cartridge at a heavy setting Always go 1 10th gram higher than the maximum recommendation To adjust the a...

Страница 6: ...en wrench to loosen the setscrew on the counterweight and rotate the counterweight as needed to bring the arm into correct lateral balance to set azimuth When the azimuth has been set you can lightly tighten the setscrew located on the top of the counterweight To make this task easier make sure the arm tube is parallel to the record surface Long thin rod 90 degrees Rotate ...

Страница 7: ...product or defect in or failure of the product This warranty does not extend to any unit whose serial number has been defaced or altered Any product that VPI determines causes a defect or malfunction due to incorrect installation modification misuse or servicing by the purchaser or service technician not authorized by VPI to perform such service will not be warranted This warranty does not cover t...

Отзывы: