Voxx PurSuit PRO9056Z Скачать руководство пользователя страница 2

PRO9056Z

Remote Start

Quick Installation Guide

1 Chirp

2 Chirp

3 Chirp

4 Chirp

5 Chirp

6 Chirp

1 Lock / Unlock Func

on

500ms

3.5sec

500ms L, DBL UL

DBL L, 500ms UL

DBL L, DBL UL

500ms L, 350ms UL

2 Accessory Lock

NA

3 Accessory Unlock

NA

4 Exterior Illumina

on

NA

5 Auto Relock

NA

6 Auto Arming

NA

7 No

�fi

ca

on Sound

NA

8 Horn Timing

16ms

30ms

40ms

50ms

10ms

9 Valet Override Method

NA

10 Driver Priority Unlock

NA

11 Silent Choice

NA

12 Park Light / Trunk Swap

NA

13 AUX Ch. 4

NA

14 AUX Ch. 5

NA

15 AUX Ch. 6

NA

16 AUX Ch. 7

NA

17 Security Pro

le

OFF

OEM Security

W/ OEM Remote Start

OFF W/ Keyless

18 Data Port Protocol

ADS

DBI

1 Chirp

2 Chirp

3 Chirp

4 chirp

5 Chirp

6 Chirp

1 Defrost Output

NA

2 RS Start No

�fi

ca

on

ON

OFF

3 RS Run

me

15min

20min

45min

60min

5min

10min

4 RS Parking Lights

Steady

Flashing

5 Engine Con

rma

on

Tach

Voltage

Data

Hybrid

6 Voltage Level

>0.5v B4 Start

<0.5v B4 Start

7 Igni

on 2 Output

Igni

ti

on

Accessory

Start

8 Igni

on 3 Output

N/A

9 Accessory Output

Accessory

Igni

on

Start

10 Transmission

NA

11 Max Crank Time

0.8sec

1.0sec

1.5sec

2.0sec

3.0sec

4.0sec

12 Diesel Delay

OFF

Diesel 5

Diesel 10

Diesel 15

Diesel 20

Diesel 30

13 Temperature Start

NA

14 Crank Dura

on

Averaging

Preset

15 RS Shock Override

NA

16 Turbo Timer

NA

17 Start Ac

va

on

Two Press

One Press

Three Press

18 RS Lock Func

on

No Change

UL Before L A

er

UL Before Start

Lock A

er Start

19 Factory Disarm Output

Single Pulse

350ms

500ms

800ms

Door Lock Timing

20 Pulse During Crank

During Crank

GWR

Igni

on

Accessory

21 Factory Arm Output

A

ft

er Start

GWR

Igni

on

Accessory

Start

22 Pulse A

er Shutdown

A

ft

er Shutdown

GWR

Igni

on

Accessory

Start

23 Addi

onal Unlock Pulse

NA

Fe

at

ur

es

Feature Bank 2

Op

ons

Fe

at

ur

es

Feature Bank 3

Op

ons

The Feature Banks below can also be programmed using the FlashLogic Weblink.

Please visit www.FlashLogic.com for more detail.

OEM Security

2020 Voxx Electronics. All Rights Reserved.

REV. B

Notifications

1 Run

me Expired

2 Remote Shutdown
3 Brake On
4 Manual Mode
5 Hood Open
6 Low / No Tach
7 Tach Programming
8 High Tach

Important Update

The default Data Port Protocol of this system is ADS. If using an 

FLCAN or other external integration module be sure to choose 

iDatalink 2-Way when flashing.

This system will also support DBI. This will require programming 

Feature Bank 2, Feature 18 to DBI.  

Remote Start

If the remote start fails to start the vehicle, the system will flash the vehicle parking 

lights to indicate the cause.

Chirp Delete

System ARM/DISARM chirps can be toggled ON or OFF without entering Feature Bank 

programming.

1. 

Turn the ignition key ON/OFF.

2. 

Press and release the valet button three (3) times.

The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This 

feature will not affect alarm trigger or programming. 

User Programmable LED

System LED notifications can be turned ON or OFF without entering Feature Bank 

programming.

1. 

Turn the ignition key ON/OFF, ON/OFF.

2. 

Press and hold valet button for five (5) seconds.

The LED will flash one (1) time for ON, two (2) times for OFF. This feature will not 

affect LED flash during programming.

Feature Programming

Remote Programming

Tach Programming

The PRO9056Z includes two (2) programmed remote controls. If required, additional 

remote controls can be programmed to the system. Remote Programming is located in 

Feature Bank 1. To enter Remote Auto Programming:

1. 

Turn the ignition key to ON.

2. 

Press and release the valet button three (3) times. The system will beep and flash 

the parking lights one (1) time.

3.  Press the Start button on each remote. The system will beep one (1) times to 

indicate the remote has been programmed. 

Data Protocol Selection 

The PRO9056Z Feature Banks can be programmed by using the valet button and remote. 

To enter Feature Bank programming:

1. 

Turn the ignition key to ON.

2. 

Press and release the valet button three (3) times. The system will beep and flash 

the parking lights one (1) time for Feature Bank 1, Remote Programming.

3.  Cycle the ignition key OFF/ON. The system will beep and flash the parking lights two 

(2) times for Feature Bank 2.

4. 

Press the valet button to cycle features. The LED will flash to display the feature 

number.

5. 

Press the Start button to cycle options. The system will beep to indicate the option 

number.

6. 

Cycle ignition key OFF/ON. The system will beep and flash the parking lights three (3) 

times for Feature Bank 3.

7. 

Press the valet button to cycle features. The LED will flash to display feature number.

8. 

Press the Start to cycle options. The system will beep to indicate the option number.

The installer must manually configure the Engine Confirmation method in Feature Bank 

3, Feature 5. The default method is “Tach”. When using the default “Tach” method, the 

vehicle tach rate must be programmed. To enter tach rate programming:

1. 

Turn the ignition key ON.

2. 

Press and release the valet button three (3) times.

3.  Turn the ignition key OFF.

4. 

Press and hold the valet button.

5. 

While holding the valet button, start the engine using the key.

6. 

Hold the valet button for approximately ten (10) seconds. If connected to the vehicle 

Tach source, the system will flash the parking lights one (1) time every second.

7. 

Release the valet button. The system will turn on the parking lights for two (2) 

seconds to indicate the tach rate is programmed.

The tach rate can also be programmed without the use of a valet button. This is helpful 

when using the OEM remote or CarLink system to control this module. To program the 

tach rate without a valet button:

1. Turn the ignition key to the ON position and start the vehicle’s engine.

2. Wait for the engine RPM to lower to a normal idle.

3. Press and hold the vehicle’s brake pedal.

4. Press the LOCK button on the OEM remote or the Carlink App.

Note:

 Programming tach signal via OEM or Telematics control is only available on 

Firmware v1.47 or Higher.

The default data port protocol of this model is ADS (iDatalink 2-Way). This model is 

capable of detecting the correct data port protocol (ADS or DBI) and automatically 

configuring Feature Bank 2; Feature 18. To initialize the detection procedure:

1. 

Press and hold the valet button.

2. 

Cycle the vehicle’s Ignition ON/OFF two (2) times.

3.  Release the valet button. 

The system will automatically detect and set the correct data port protocol, ADS or DBI.

Note: 

This feature is only available on module firmware v2.0 or higher.

This system can provide OEM level security. The system will monitor and trigger by the 

analog hood input and all entry zone inputs from the FLCAN or other integration modules. 

When an entry zone is detected the system will beep the vehicle horn and flash the 

parking lights. This feature must be activated in Feature Bank 2, Feature 17.

Operation

To arm the system, press the start button one (1) time.

To disarm the system, press the start button two (2) times.

To start the system, press and hold the start button for three (3) seconds.

Valet Override Procedure

To disarm the system without the use of a remote, turn the ignition key to ON and press 

the valet button one (1) time.

For Complete Installation Guide and Technical Support Visit

www.voxxuniversity.com

Or Call 1-800-225-6074

Отзывы: