![Voxx PurSuit PRO9056Z Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/voxx/pursuit-pro9056z/pursuit-pro9056z_quick-installation-manual_1052130002.webp)
PRO9056Z
Remote Start
Quick Installation Guide
1 Chirp
2 Chirp
3 Chirp
4 Chirp
5 Chirp
6 Chirp
1 Lock / Unlock Func
�
on
500ms
3.5sec
500ms L, DBL UL
DBL L, 500ms UL
DBL L, DBL UL
500ms L, 350ms UL
2 Accessory Lock
NA
3 Accessory Unlock
NA
4 Exterior Illumina
�
on
NA
5 Auto Relock
NA
6 Auto Arming
NA
7 No
�fi
ca
�
on Sound
NA
8 Horn Timing
16ms
30ms
40ms
50ms
10ms
9 Valet Override Method
NA
10 Driver Priority Unlock
NA
11 Silent Choice
NA
12 Park Light / Trunk Swap
NA
13 AUX Ch. 4
NA
14 AUX Ch. 5
NA
15 AUX Ch. 6
NA
16 AUX Ch. 7
NA
17 Security Pro
fi
le
OFF
OEM Security
W/ OEM Remote Start
OFF W/ Keyless
18 Data Port Protocol
ADS
DBI
1 Chirp
2 Chirp
3 Chirp
4 chirp
5 Chirp
6 Chirp
1 Defrost Output
NA
2 RS Start No
�fi
ca
�
on
ON
OFF
3 RS Run
�
me
15min
20min
45min
60min
5min
10min
4 RS Parking Lights
Steady
Flashing
5 Engine Con
fi
rma
�
on
Tach
Voltage
Data
Hybrid
6 Voltage Level
>0.5v B4 Start
<0.5v B4 Start
7 Igni
�
on 2 Output
Igni
ti
on
Accessory
Start
8 Igni
�
on 3 Output
N/A
9 Accessory Output
Accessory
Igni
�
on
Start
10 Transmission
NA
11 Max Crank Time
0.8sec
1.0sec
1.5sec
2.0sec
3.0sec
4.0sec
12 Diesel Delay
OFF
Diesel 5
Diesel 10
Diesel 15
Diesel 20
Diesel 30
13 Temperature Start
NA
14 Crank Dura
�
on
Averaging
Preset
15 RS Shock Override
NA
16 Turbo Timer
NA
17 Start Ac
�
va
�
on
Two Press
One Press
Three Press
18 RS Lock Func
�
on
No Change
UL Before L A
�
er
UL Before Start
Lock A
�
er Start
19 Factory Disarm Output
Single Pulse
350ms
500ms
800ms
Door Lock Timing
20 Pulse During Crank
During Crank
GWR
Igni
�
on
Accessory
21 Factory Arm Output
A
ft
er Start
GWR
Igni
�
on
Accessory
Start
22 Pulse A
�
er Shutdown
A
ft
er Shutdown
GWR
Igni
�
on
Accessory
Start
23 Addi
�
onal Unlock Pulse
NA
Fe
at
ur
es
Feature Bank 2
Op
�
ons
Fe
at
ur
es
Feature Bank 3
Op
�
ons
The Feature Banks below can also be programmed using the FlashLogic Weblink.
Please visit www.FlashLogic.com for more detail.
OEM Security
2020 Voxx Electronics. All Rights Reserved.
REV. B
Notifications
1 Run
�
me Expired
2 Remote Shutdown
3 Brake On
4 Manual Mode
5 Hood Open
6 Low / No Tach
7 Tach Programming
8 High Tach
Important Update
The default Data Port Protocol of this system is ADS. If using an
FLCAN or other external integration module be sure to choose
iDatalink 2-Way when flashing.
This system will also support DBI. This will require programming
Feature Bank 2, Feature 18 to DBI.
Remote Start
If the remote start fails to start the vehicle, the system will flash the vehicle parking
lights to indicate the cause.
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering Feature Bank
programming.
1.
Turn the ignition key ON/OFF.
2.
Press and release the valet button three (3) times.
The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This
feature will not affect alarm trigger or programming.
User Programmable LED
System LED notifications can be turned ON or OFF without entering Feature Bank
programming.
1.
Turn the ignition key ON/OFF, ON/OFF.
2.
Press and hold valet button for five (5) seconds.
The LED will flash one (1) time for ON, two (2) times for OFF. This feature will not
affect LED flash during programming.
Feature Programming
Remote Programming
Tach Programming
The PRO9056Z includes two (2) programmed remote controls. If required, additional
remote controls can be programmed to the system. Remote Programming is located in
Feature Bank 1. To enter Remote Auto Programming:
1.
Turn the ignition key to ON.
2.
Press and release the valet button three (3) times. The system will beep and flash
the parking lights one (1) time.
3. Press the Start button on each remote. The system will beep one (1) times to
indicate the remote has been programmed.
Data Protocol Selection
The PRO9056Z Feature Banks can be programmed by using the valet button and remote.
To enter Feature Bank programming:
1.
Turn the ignition key to ON.
2.
Press and release the valet button three (3) times. The system will beep and flash
the parking lights one (1) time for Feature Bank 1, Remote Programming.
3. Cycle the ignition key OFF/ON. The system will beep and flash the parking lights two
(2) times for Feature Bank 2.
4.
Press the valet button to cycle features. The LED will flash to display the feature
number.
5.
Press the Start button to cycle options. The system will beep to indicate the option
number.
6.
Cycle ignition key OFF/ON. The system will beep and flash the parking lights three (3)
times for Feature Bank 3.
7.
Press the valet button to cycle features. The LED will flash to display feature number.
8.
Press the Start to cycle options. The system will beep to indicate the option number.
The installer must manually configure the Engine Confirmation method in Feature Bank
3, Feature 5. The default method is “Tach”. When using the default “Tach” method, the
vehicle tach rate must be programmed. To enter tach rate programming:
1.
Turn the ignition key ON.
2.
Press and release the valet button three (3) times.
3. Turn the ignition key OFF.
4.
Press and hold the valet button.
5.
While holding the valet button, start the engine using the key.
6.
Hold the valet button for approximately ten (10) seconds. If connected to the vehicle
Tach source, the system will flash the parking lights one (1) time every second.
7.
Release the valet button. The system will turn on the parking lights for two (2)
seconds to indicate the tach rate is programmed.
The tach rate can also be programmed without the use of a valet button. This is helpful
when using the OEM remote or CarLink system to control this module. To program the
tach rate without a valet button:
1. Turn the ignition key to the ON position and start the vehicle’s engine.
2. Wait for the engine RPM to lower to a normal idle.
3. Press and hold the vehicle’s brake pedal.
4. Press the LOCK button on the OEM remote or the Carlink App.
Note:
Programming tach signal via OEM or Telematics control is only available on
Firmware v1.47 or Higher.
The default data port protocol of this model is ADS (iDatalink 2-Way). This model is
capable of detecting the correct data port protocol (ADS or DBI) and automatically
configuring Feature Bank 2; Feature 18. To initialize the detection procedure:
1.
Press and hold the valet button.
2.
Cycle the vehicle’s Ignition ON/OFF two (2) times.
3. Release the valet button.
The system will automatically detect and set the correct data port protocol, ADS or DBI.
Note:
This feature is only available on module firmware v2.0 or higher.
This system can provide OEM level security. The system will monitor and trigger by the
analog hood input and all entry zone inputs from the FLCAN or other integration modules.
When an entry zone is detected the system will beep the vehicle horn and flash the
parking lights. This feature must be activated in Feature Bank 2, Feature 17.
Operation
To arm the system, press the start button one (1) time.
To disarm the system, press the start button two (2) times.
To start the system, press and hold the start button for three (3) seconds.
Valet Override Procedure
To disarm the system without the use of a remote, turn the ignition key to ON and press
the valet button one (1) time.
For Complete Installation Guide and Technical Support Visit
www.voxxuniversity.com
Or Call 1-800-225-6074