8812 Module
Cover Control Module
Cover Control Module Owner’s
Manual (R1.00)
PAGE-3
5.
Cover Control Module mounting location
6.
Operations
A)
Calibration process:
Description: A calibration process must be completed during the installation to ensure that the
system can properly detect the end points.
Steps:
1.
Send 3x RKE Unlock with normal press (like 3x Lock start press). The bed cover should move
to fully open at a slow speed.
2.
Send 3x RKE Lock with normal press. The bed cover should move to fully close at a slow speed.
B)
Commands
Opening the cover: There are several methods to do this operation.
1.
Press and release the OEM remote UNLOCK button to open the cover.
2.
Tap the COVER OPEN icon from the APP
3.
Press and release the button
“
1/
2”
on the 5button keypad.
Closing the cover: There are several methods to do this operation.
4.
Press and release the OEM remote LOCK button to open the cover.
5.
Tap the COVER CLOSE icon from the APP
6.
Press and release the button
“
9/0
”
on the 5button keypad. 9/0