Voxx Electronics Prestige APSSEC Скачать руководство пользователя страница 2

APSSEC

Security w/Keyless Entry

Quick Installation Guide

For Complete Installation Guide and Technical Support 

Please Visit

www.voxxuniversity.com

Or Call

1-800-225-6074

Notifications

Remote Programming

1 Chirp

2 Chirp

3 Chirp

4 Chirp

5 Chirp

6 Chirp

1 Lock / Unlock Func

on

500ms

3.5sec

500ms L, DBL UL

DBL L, 500ms UL

DBL L, DBL UL

500ms L, 350ms UL

2 Igni

on Lock

OFF

ON

3 Igni

on Unlock

OFF

Unlock All

Unlock Driver

4 Exterior Illumina

on

OFF

With Arm

With Disarm

With Arm & Disarm

5 Auto Relock

OFF

Auto Lock Only

Auto Lock & Arm

6 Auto Arming / Locking

OFF

Auto Arm Only

Auto Lock & Arm

7 No

�fi

ca

on Sound

Both

Siren

Horn

8 Horn Timing

16ms

30ms

40ms

50ms

10ms

9 Valet Override Method

Valet

Custom Code

Stand Alone Valet

10 Driver Priority Unlock

OFF

ON

11 Silent Choice

OFF

From Transmi

er

OEM Style

12 Security Pro

le

All On

Doors O

Hood/trunk O

All O

All On w/ OEM RS

13 Door Trigger Input

Nega

ti

ve

Posi

ve

14 Park Light / Trunk Swap

OFF

ON

15 Data Port Protocol

ADS

DBI

16 1 or 2 Wire Disarm

2 Wire

1 Wire

17 Disarm Input

120ms Dr OR Pass

80ms Dr OR Pass

120ms, UL & Light

80ms, UL & Light

18 Arm 1 Input

Auto Detect

Posi

ve

Nega

ve

19 Disarm 1 Input

Auto Detect

Posi

ve

Nega

ve

20 Arm 2 Input

Auto Detect

Posi

ve

Nega

ve

21 Disarm 2 Input

Auto Detect

Posi

ve

Nega

ve

22 Trunk Shunt Input

Auto Detect

Posi

ve

Nega

ve

23 Dome Light Delay Timer

OFF / Program

15sec

30sec

45sec

60sec

120sec

24 Alarm Trigger Length

30sec

45sec

60sec

90sec

120sec

Features

Op

ons

Fe

at

ur

es

Negative Output Control (NOC)

AUX Output Control

Factory Keyless Upgrade

Shock Sensor

Negative output control allows any NOC to be programmed for any one of the options 

below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.

Any AUX output can be configured using the AUX Control Menu. This feature is only 

accessible via FlashLogic Weblink or Weblink Mobile.

The shock sensor should be mounted to a solid surface in the center of the vehicle. 

Once mounted the shock sensor will require adjustment.

To increase sensitivity: Turn adjustment dial clockwise.

To decrease sensitivity: Turn adjustment dial counter clockwise.

To test sensitivity, strike the vehicle with an open palm. Adjust the dial to provide 

coverage to as much of the vehicle as possible.

Important Update:

The default data port protocol of this system is ADS. When flashing the FLCAN, or other integration module, be sure to choose iDatalink 2-Way as the installation method.

This module will also support DBI. This will require programming Feature Bank 2, Feature 15 to DBI. For Technical Support Visit www.voxxuniversity.com or Call 1-800-225-6074.

Feature Programming

Dome Delay Programming

The APSSEC Feature Banks can be programmed by using the valet button and the OEM or 

Prestige remote. To enter Feature Bank programming:

1. 

Turn the ignition key to ON.

2. 

Press and release the valet button three (3) times. System will beep and flash lights 

one (1) time for Feature Bank 1, Remote Programming.

3. 

Cycle ignition key OFF/ON. System will beep and flash lights two (2) times for 

Feature Bank 2.

4. 

Press valet button to cycle features. LED will flash to display feature number.

5. 

Press lock button to cycle options. System will beep to indicate option number.

To exit Programming cycle ignition key OFF and wait ten (10) seconds. The System will also 

automatically exit programming after sixty (60) seconds of no activity.

This system can be programmed to ignore the vehicle’s theater dimming dome light. This 

feature will be used when connecting the door trigger input to the dome light circuit for 

alarm trigger. Note: Vehicle windows should be open to prevent accidental locking of keys 

in the vehicle.

Start with all doors closed and the vehicle dome light off.

1. 

Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.

2.  Open and close the driver door.

The system will monitor the dome light circuit. When the dome light turns off the system 

will set the delay time and add an additional two (2) seconds.

Dome Delay Reset

1. Key ON/OFF, ON/OFF, ON/OFF.

2. Press and hold valet button for five (5) seconds.

The system will beep one (1) time to indicate reset is complete.

The Feature Bank below can also be programmed using the FlashLogic Weblink or Weblink Mobile.

Please visit www.FlashLogic.com for more detail.

The APSSEC does not include an RF remote kit. The RF remote kit Includes two (2) remotes,  

one (1) antenna, and one (1) cable. When added, remotes must be programmed to 

the system. Remote Programming is located in Feature Bank 1. To enter Remote Auto 

Programming:

1. 

Turn the ignition key to ON.

2. 

Press and release the valet button three (3) times. System will beep and flash the 

parking lights one (1) time.

Press the lock button on each remote. The system will beep one (1) time to indicate the 

remote has been programmed. If programming one (1) button remotes, press the Start 

button. Only primary remote functions are auto programmed. This Includes Lock, Unlock, 

and Trunk/Start.

If using AUX output control, you must manually program the AUX output channels to 

the remote. Please see the complete installation guide for manual remote programming 

instruction.

Note: If programming 2-Way remotes, wait for the remote to beep before programming 

additional remotes. This beep is confirmation that a 2-Way response has been received 

from the main module.

LED Output

Ch. 7 AUX Output

Horn Output

Ground While Armed 

(GWA)

Ground While Disarmed 

(GWD)

Ch. 3 ALT Output
Ch. 4 AUX Output
Ch. 5 AUX Output
Ch. 6 AUX Output

Lock Output
Unlock Output

Trunk Output

2nd Unlock Output

Dome Light Output
Head Light Output

1 Second Pulse
5 Second Pulse
10 Second Pulse
15 Second Pulse

20 Second Pulse
30 Second Pulse
Push & Hold
Latch ON/OFF

1 Shock

2 Trunk/Hood

3 Door

Data Protocol Selection 

REV. B

2020 Voxx Electronics. All Rights Reserved.

The APSSEC can be used without transmitters as a Factory Keyless Alarm Upgrade. Arm / 

Disarm 1 inputs will be connected to the Driver Door Lock Motor. Arm / Disarm 2 inputs 

will be connected to the Passenger Door Lock Motor and / or the Lock Switch. The control 

polarity, by default, will be detected automatically upon power up. The Control polarity can 

also be manually configured using Feature Bank 2, Features 18-21.

Note: 

If this feature is supported by FLCAN Arm / Disarm Wires are not required for install. 

The Trunk Shunt input will be used if the vehicle is equipped with a factory power trunk 

/ hatch release. If equipped, connect the Trunk Shunt input to the factory trunk release 

trigger wire. The control polarity, by default, will be detected automatically upon power up. 

The control polarity can also be manually configured using Feature Bank 2, Feature 22.

Trunk Trigger

Door Trigger

Instant Trigger

N.C. Door Trigger

Pre-Warn Shock Trigger

Hood Trigger

Fill Shock Trigger

Alarm

When the alarm is triggered the system will provide feedback to the user. Upon disarm, 

the system will beep 4x and flash the LED to indicate the Alarm Trigger Zone.

Chirp Delete

System ARM/DISARM chirps can be toggled ON or OFF without entering the Feature 

Bank programming.
1. 

Turn the ignition key ON/OFF.

2. 

Press and release the valet button three (3) times.

The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This 

feature will not affect alarm trigger or programming. 

User Programmable LED

System LED notifications can be turned ON or OFF without entering Feature Bank 

programming.
1. 

Turn the ignition key ON/OFF, ON/OFF.

2. 

Press and hold valet button for five (5) seconds.

The LED will flash one (1) time for ON, two (2) times for OFF. This feature will not affect 

LED flash during programming.

The default data port protocol of this model is ADS (iDatalink 2-Way). This model is 

capable of detecting the correct data port protocol (ADS or DBI) and automatically 

configuring Feature Bank 2; Feature 18. To initialize the detection procedure:

1. 

Press and hold the valet button.

2. 

Cycle the vehicle’s Ignition ON/OFF two (2) times.

3. 

Release the valet button. 

The system will automatically detect and set the correct data port protocol, ADS or DBI.

Note: 

This feature is only available on module firmware v2.0 or higher.

PIC Input Control

Programmable Input Control allows any PIC be configured to one of the options listed 

below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.

Notes

Отзывы: