42
Indication of RX_LEV at -100 dBm
-104 dB
-96 dB
Indication of RX_LEV at -45 dBm
-49 dB
-41 dB
Quality of RX_LEV (RX_QUAL)
No more than 2
Table 10.2: DCS frequency band test parameter
3: PCS frequency band
The number of Low band channel is 512, transmit frequency of low band channel is 1850MHz, receive
frequency is 1930MHz
The number of Intermediate band channel is 665, transmit frequency of intermediate band channel is
1880.6MHz, receive frequency is 1960.6MHz
The number of High band channel is 810, transmit frequency of high band channel is 1910MHz, receive
frequency is 1990MHz
Test parameter:
Ready to executive EGSM Test
Lower limit
Upper limit
Transmitting average phase error when at min and max power
transmit (average root value)
5
degree
Transmitting average phase error when at min and max power
transmit (peak value)
20
degree
Transmitting average frequency error when at min and max
power transmit
-171Hz +171Hz
Transmitting power error at NO.5 power class (20dBm) on
CH700
-2db +2db
Transmitting power error at NO.10 power class (10dBm) on
CH62
-3db +3db
Transmitting power error at NO.15 power class (0dBm) on
CH62
-3db +3db
Transmitting average power error when at min and max power
transmit
In PCS technique guideline
Receive bit error test of RES II ( at -102 dBm)
2%
Receive frame erasure rate of RES II ( at -102 dBm)
0.12%
Indication of RX_LEV at -100 dBm
-104 dB
-96 dB
Indication of RX_LEV at -45 dBm
-49 dB
-41 dB
Quality of RX_LEV (RX_QUAL)
No more than 2
Table 10.2: PCS frequency band test parameter
10.2: analyse equipment and maintain tool in common use:
CMU200 / HP8960 / CMD55 -- -- signal generator
HP8594E -- -- Spectrum analyzer
HP854810 / HP54520 -- -- oscillograph
HP34410A -- -- multimeter
HP6623A / LPS-105-AMRFL -- -- DC
ERSA 60A / HAKO926 -- -- electric iron
STEINEL-HL2305LCD / HAKO851
10.3
:
Notice:
Products with power should be repaired by the experienced engineer, any other person use this
manual to repair product nonstandard may cause electric damage or even person wound
There should be a credible working zone----ESDs (Electro-Static sense discharge), then it could be
used safety to avoid danger of Electro-Static discharge. This working zone must be set according to
these as follows:
Working flat ---- Each working flat must lay contradict Electro-Static mat. For the safety of equipment
with power, it should connect to the commonality ground through a resistance of 1.2M
Hand ring ---- A device made of soft line that can release Electro-Static fast. Hand ring’s soft line
connect to commonality ground with a resistance of 5.2K to 1.2M inter
Container ---- all of the container must be conductor
Maintain engineer should take care of self-protect, such as using blinker, glove, avoid inbreathe gas
Содержание W420
Страница 1: ...Voxtel Repair Manual Item W420 ...
Страница 23: ...23 3 LDO circuit ...
Страница 24: ...24 Cameramodule control circuit ...