Page 11 of 22
Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 |
DOC-MN-008-03, VCCS300 User Manual
Component Temperatures
Evaluating the VCCS300 product in the end application
To ensure the product is operating within its ratings in the end application the following procedure should be performed during the design stage.
1.
Setup the application in worst case conditions, considering mains voltage, output power, ambient temperature, mounting orientation, airflow, and cooling
restrictions.
2.
Install thermocouples in the positions listed below using glue to hold the thermocouples in place.
3.
Power the system and monitor the temperatures until they reach steady state.
4.
Ensure that all temperatures remain below recommended temperatures under normal conditions and do not exceed maximum temperatures under worst
case conditions. It is good practice to leave some margin in the design.
Description
Reference
Measurement
Position
Recommended
temperature
Maximum allowed
temperature
Fuse
FS1
Body Centre
100°C
125°C
Filter Inductors
L1 & L2
Winding Top (Starred)
110°C
130°C
Varistor
V1
Body Centre
80°C
85°C
Electrolytic capacitor
C1
Body Centre
90°C
105°C
Transformer
PCB1
Centre (Starred)
115°C
130°C
Operation of components above the recommended temperatures will result in reduced lifetime of the unit and invalidate the warranty.