Settings 

 

Start-up 

The following settings are to be made for start-up:  

-

 

Board battery disconnection threshold low voltage in V  

-

 

Board battery start threshold in V 

-

 

Activation / Deactivation audible alarm device 

-

 

Solar power (see operation Solar Computer) 

 

Access to the Menu 

The menu for the switching thresholds and alarm device settings is activated by pressing and holding the key "Battery" . 

The first menu item will be displayed.  

 

Menu - Navigation and Exit 

The individual settings can be run through consecutively using the key "Battery"  . Use the arrow keys 

 to change 

the settings. Quick setting of large values is done by pressing and holding the arrow keys 

. After the last menu item, 

the display returns to normal operating mode. 

 

Menu Items 

At each menu item, the symbol "Set" will be displayed at the upper edge of the menu.  

 

 

 

Board battery disconnection threshold in V 

 

 

 

Board battery start threshold in V 

 

 

 

 

Activation / deactivation audible alarm device 

The audible alarm can generally be activated or deactivated.  

"On" or "Off" will be displayed correspondingly at the upper menu margin. 

 

General Information: 

 

Cleaning: 

We recommend to use a damp microfibre cloth with pure water or, if necessary, with a little soap. Make sure, that no 

liquid flows along the display screen or the edges of the front panel.  

 

Never use solvents, aggressive household cleaners, or  scratching  and  abrasive agents or objects to clean the 

front panel and particularly the display itself.  

 

 

 

Содержание VPC Terra

Страница 1: ...l free output Solar Computer Suitable for all VOTRONIC solar charging controllers since year of production 2014 Instantaneous solar power in W Instantaneous solar current in A Charged solar capacity in Ah Charged solar power in kWh Please read the installation instructions operating manual and safety instructions page 7 completely prior to starting connection and placing the unit into operation Th...

Страница 2: ...nic system and full utilization of the storage space which might be located behind Solar Controller The VOTRONIC Solar Controller is connected directly at the display panel by a plug and go 6 pole data cable see available accessories Tank Sensors A VOTRONIC tank sensor with continuous output signal is to be installed at the corresponding tank according to the installation instructions The connecti...

Страница 3: ...tput max 1 A The output serves as control signal for an external controllable main switch Switch Unit The main switch can be operated from the display panel In addition the system provides an automatic disconnection in case of overvoltage or low voltage Battery Protector Function In active condition ON the battery voltage 12 V or 24 V is at disposal here The output is protected from overload by a ...

Страница 4: ...mination can also be switched off manually by shortly pressing the main switch see figure on the left side The brightness of the LED lamps is coupled with the illumination of the display If the display is dark the LED lamps will also be dimmed to a minimum Brightness Display and LED The brightness of the display illumination and the LED lamps can be changed at any time by pressing and holding 3 se...

Страница 5: ...After initial start up the nominal capacity of the system must be adjusted at the solar computer to ensure correct display of the capacity Set the display manually to 100 when the sun is shining and the full charging current is flowing Adjustment is effected by setting the display to current A and by pressing the key Solar for more than 3 seconds until Set 100 is displayed This procedure can be re...

Страница 6: ...ssing and holding the arrow keys After the last menu item the display returns to normal operating mode Menu Items At each menu item the symbol Set will be displayed at the upper edge of the menu Board battery disconnection threshold in V Board battery start threshold in V Activation deactivation audible alarm device The audible alarm can generally be activated or deactivated On or Off will be disp...

Страница 7: ...r work on the electric system If the user is not able to draw from the manual which characteristic values are valid for a unit or which regulations are to be observed a specialist is to be consulted The user buyer is responsible for the observation of construction and safety regulations of any kind Keep children away from the batteries Observe the safety regulations of the battery manufacturer The...

Страница 8: ...000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in the household waste The product is RoHS compliant It complies with the directive 2011 65 EU for Reduction of Hazardous Substances in electrical and electronic equipment Delivery Scope Available Accessories 1 Pc VPC Terra Display and Control Panel Switch Unit 40 Order No 2071 4 Pcs Fastening Screws ...

Отзывы: