--4--
2
In combination with electroblock
"EBL"
with use of existing cables and fuses, the + cable to the
STARTER battery must be disconnected:
During mains operation, the STARTER battery will be charged by the EBL. Then, the recharging branch of the
charging converter is not active.
Special feature: Voltage display on older EBL designs without a separate charging/measuring circuit for the STARTER
battery:
When the charging converter is installed on an older EBL design, the voltage of the STARTER battery may not be displayed
when the charging converter is switched off. In the event that the voltage is not displayed, a jumper wire must be installed
between "+IN 12 V" and "EBL START In". Due to the system, the voltage of the STARTER battery will not be displayed
correctly at the EBL while driving. During EBL mains operation, the recharging branch of the charging converter for
charging/trickle charging of the STARTER battery is active. See EVS, page 5.