--8--
Unit Settings:
Carefully move the
2 micro slide switches
at the lateral panel of the
unit to the desired position using a small screw-driver.
The
control levers
are shown in
white
.
1.)
How to Set the Charging Program Battery Type "BOARD"- (Design,
Technology):
Four (4) charging programs
for the different battery types are stored in the unit.
They can be selected by means of the shown
2 slide switches
:
If not being specified divergently by the battery manufacturer, the suitable charging program for
the BOARD supply battery can be determined by means of the following description and the
technical data (voltage rates U1 and U2).
The possible parallel/floating operation with consumer loads 12 V being connected to the
BOARD battery is also automatically considered by all charging programs.
TS
= Temperature Sensor (Effect with/without connection of the temperature sensor)
Charging Programs for
Lead
Batteries (Acid, Gel, AGM)
:
Charging programs 1-3, charging voltage rates and temperature equalization for batteries in lead
technology:
1
"Lead Acid / AGM 1"
Switch Position
U1=14.40 V U2=13.50 V
2-6 h
Universal charging program for
acid-lead-acid batteries
acc. to DIN 57 510/
VDE 0510 for charging and trickle charging of
supply (BOARD) batteries.
Ensures short charging times, high charging factor and
acid mixing for open standard batteries and closed,
SLA, low-maintenance, maintenance-free "non-solid
electrolyte", "lead-acid", drive, lighting, solar and
heavy-duty batteries. Also suitable for recently
developed batteries (low-antimonous, with silver-alloy,
calcium or similar) and batteries with low (L) and very low (VL) water consumption.
Adapted to closed, gas-tight
AGM
(absorbed glass mat) / lead-fleece batteries
VRLA
with indication of the charging voltage
"
14.4 V
".
2
"Gel"
Switch Position
U1=14.40 V U2=13.80 V
6-12 h
Adapted to closed, gas-tight
Gel/dryfit
batteries
VRLA
with
determined electrolyte, which are
generally requiring longer dwell times U1 to achieve
particularly high capacity storage and to avoid deep
discharge (becoming deaf) of the battery, such as
EXIDE, Sonnenschein, "dryfit", Varta, Bosch, Banner,
Mobil Technology etc. If not being specified divergently
by the battery manufacturer, also recommended for
batteries in round cell technology, such as EXIDE
MAXXIMA (DC).