Votronic S1250 Скачать руководство пользователя страница 3

- 3 - 

Operating State Solar Controller 

(Sun Symbol): 

Depending on the solar controller, the operating state of the solar controller is indicated by the sun symbol.  

 

No sun: Solar power is not at disposal; the solar controller is in stand-by mode. 

 

Full sun: Solar power is at disposal, maximum possible charge 

 

Flashing sun:  The controller limits the current because of a full or almost full battery to avoid battery 

overcharging.  For determination of the possible solar power, the battery must be discharged by a consumer 
(such as lighting) until the solar controller supplies full power, and the sun symbol stops flashing. 

 
Function of Votronic controllers MPP 150, MPP 225, MPP 320, MPP 324, MPP 484: 

 

No sun: Solar power is not at disposal; the solar controller is in stand-by mode. 

 

Flashing sun: Proper operation of the controller. Control to “Maximum Power Point” (MPP). 

 
 
 

General Information 

 

Cleaning:

 

We recommend to use a damp microfibre cloth with pure water or, if required, with water with a few soap.   
Take care that no liquid flows along the display screen or the edges of the front panel! 

 
Never use solvents, aggressive household cleaners, and scratching or abrasive agents or objects to clean the 
front panel and particularly the display itself.  
 

 
 

Trouble-Shooting:

 

No display at all: 

a)

 

Reverse battery, fuse released Check! 

b)

 

Battery is totally discharged, below 7 volts Recharge immediately! 

c)

 

Connection cable is interrupted, damaged, or it is not inserted: Check! 

 
„Hieroglyphs“ on the display: 

a)

 

The internal check programs of the unit have found an (memory) error: 
Withdraw the cable connector for 10 seconds. After that, an initial start-up is to be executed as described above.

 

 

 
 
 

Technical Data: 

 

System:

 

Nominal Voltage: 

12 V and 24 V 

Operating Voltage Range: 

8...32 V (of Solar Controller) 

Current Consumption: 

3...30 mA, depending on illumination 

Measuring Range: 

20 Wp ... 550 Wp 

 

Display Unit (LCD Display): 

Technology: 

LC Display with specific segments

 

Representation Surface: 

49 x 28 mm

 

Illumination: 

white LED

 

 

Dimensions (mm): 

80 x 85 x 24

 

Assembly Dimensions (mm): 

approx. 66 x 72

 

Weight: 

approx. 55 g 

 

 

Содержание S1250

Страница 1: ...cable can cause malfunction which is not covered by guaranty Installation and Connection The small mounting depth approx 27 mm of the electronic system allows flush mounting into furniture boards to ensure that an optimum installation place can always be chosen The clear opening of the cutout is min 71 x 66 mm to ensure safe alignment of the front panel Please use the delivered drilling jig which ...

Страница 2: ...ically The display continues showing the same data The display illumination is reactivated by pressing any button The proper function of the button will be effected by pressing the button a second time Solar Displays Use the button 1 to change to the next page of the measured and displayed values of the solar system The buttons 1 or 2 are used to change to the next or previous page of the display ...

Страница 3: ...th pure water or if required with water with a few soap Take care that no liquid flows along the display screen or the edges of the front panel Never use solvents aggressive household cleaners and scratching or abrasive agents or objects to clean the front panel and particularly the display itself Trouble Shooting No display at all a Reverse battery fuse released Check b Battery is totally dischar...

Страница 4: ...material damage Never use solvents or aggressive household cleaners for cleaning of the display The warranty period is 24 months from the purchase date against presentation of the sales slip or invoice The warranty will be void in case of any inappropriate utilisation of the unit if it is used beyond the technical specification in case of improper operation or external intervention We do not assum...

Отзывы: