Votronic S1250 Скачать руководство пользователя страница 1

 

Installation and Operating Manual 

 

LCD Solar Computer S 

 

No.  1250 

 
Precise display of all important values, adapted to all Votronic solar controllers. 
 
The following values are displayed: 

 

 

- Charging current (A) 
- Solar battery voltage (V) 
- Solar power (W) 
- Solar power as bar graph 
- Solar current meter (Ah and Wh) 

 

The LCD Solar Computer S has been particularly designed for operation in connection with all VOTRONIC Solar controllers 
since serial number 13V01.0000. A large display with time-controlled illumination ensures excellent legibility. The solar 
charging current, the solar power and the voltage of the solar battery are displayed. The instantaneous capacity of the 
solar modules is constantly displayed as bar graph in steps of 10 % at the margin of the display.  
The current meter function counts the “yielded” ampere hours and watt hours, thus simplifying the control of the solar 
system. The counter values can be reset to zero at any time and at discretion. 
 
The dimensions of the unit are perfectly adapted to the VOTRONIC modular system. The VOTRONIC modular system 
includes the tank display units (fresh and sewage water, as well as feces), the LCD series (battery computer, voltmeter, 
ammeter and thermometer), as well as the switch and fuse panels.

 

 

Please read the mounting instructions and operating manual including the safety regulations 
completely prior to starting connection and start-up. 
 

The included control cable is specifically designed and tested for this application. It has to be used 
necessarily for a proper function of the device. Using a seemingly similar cable can cause malfunction, 
which is not covered by guaranty. 

 

Installation and Connection 

The small mounting depth (approx. 27 mm) of the electronic system allows flush mounting into furniture boards to 
ensure, that an optimum installation place can always be chosen.  The clear opening of the cutout is min. 71 x 66 mm to 
ensure safe alignment of the front panel. Please use the delivered drilling jig, which has been designed to consider 
combination with further display panels.

 

If possible, the rear cutout opening should be covered with electrically nonconducting material to ensure efficient 
protection of the electronic system and full utilization of the storage space, which might be located behind. 

The delivered control cable of 5 m length is used to connect the display unit to the VOTRONIC Solar Controller 
(connection “Solar Display”). The connection is executed ready to be plugged in, and the cable should be laid according to 
the safety instructions. 

 

Now the unit is ready for operation. 

If the length of the control cable is not sufficient for connection of the connection unit, the cable extension of 5 m length, 
order No. 2005, being available as accessory can be used. The total cable length is then 10 m. 
 

Initial Start-up:

 

Connect the solar controller according to the instructions to be ready for operation, and make the plug-type connection 
between display and VOTRONIC Solar Controller. Now, also the Solar Computer is ready for operation. 
 

Solar Nominal Capacity: 

The nominal capacity of the system must be adjusted at the solar computer after initial start-up and after each change of 
the solar system to ensure correct display of the bar graph. Adjust the display manually to 100 % (see page 2: “Capacity”), 
when the sun shines and the full charging current flows.

 

Содержание S1250

Страница 1: ...cable can cause malfunction which is not covered by guaranty Installation and Connection The small mounting depth approx 27 mm of the electronic system allows flush mounting into furniture boards to ensure that an optimum installation place can always be chosen The clear opening of the cutout is min 71 x 66 mm to ensure safe alignment of the front panel Please use the delivered drilling jig which ...

Страница 2: ...ically The display continues showing the same data The display illumination is reactivated by pressing any button The proper function of the button will be effected by pressing the button a second time Solar Displays Use the button 1 to change to the next page of the measured and displayed values of the solar system The buttons 1 or 2 are used to change to the next or previous page of the display ...

Страница 3: ...th pure water or if required with water with a few soap Take care that no liquid flows along the display screen or the edges of the front panel Never use solvents aggressive household cleaners and scratching or abrasive agents or objects to clean the front panel and particularly the display itself Trouble Shooting No display at all a Reverse battery fuse released Check b Battery is totally dischar...

Страница 4: ...material damage Never use solvents or aggressive household cleaners for cleaning of the display The warranty period is 24 months from the purchase date against presentation of the sales slip or invoice The warranty will be void in case of any inappropriate utilisation of the unit if it is used beyond the technical specification in case of improper operation or external intervention We do not assum...