background image

- 5 - 

Tips for Single and Double Tank Displays:  

 

 
 

If the connection is obviously correct and malfunctions are suspected, please check the following: 
Possible causes, if the displayed value is permanently < 10%: 

a.

 

Cable 5 = Tank +, switched, to the tank transmitters, 12 V / 24 V:

 

     

Interrupted or short-circuited  

 Check

 

b.

 

Cable 4 = Measuring signal of the tank transmitter:  

Short-circuited to ground  

 Check

 

Possible causes, if the displayed value is permanently 100%: 

a.

 

Cable 1 = Board Battery “-“ or Body ground to the tank: 

Interrupted 

 Check

 

b.

 

Cable 4 = Measuring signal of the tank transmitter:  

Short-circuited to plus  

 Check

 

Performance Test Display: Release terminal 4 = measuring signal of the tank transmitter and connect 
terminal 4 (for reasons of testing) to:

 

a.

 

Terminal 1 = Board Battery “-“ or Body ground  

 Display must drop to 3 %

 

b.

 

Terminal 5 = Tank +, switched 

 The display should increase to 100% 

 

Then, the display function is basically correct, and the cause has to be searched with regard to the tank transmitter. 

 
 

2 Tanks at one display: 

The individual tank displays can also be assigned for selective measuring, such as  
inside / outside tank, summer/winter operation, additional tank etc. 

For switching, separate switches 2xUM are suitable, such as:   

Switch Panel 16 A S   

Order No. 1289 

Switch Panel  2 x 16 A S    Order No. 1291

 

With the double selector switches the cables 

  4 = Tank signal (measuring signal) and 

  5 = Tank + (Plus) 

can be switched selectively to either of the tank measuring sensors. 

The cables 1 = Board Battery “-“ (Minus) or Body Ground remain always connected. 
 
 
 

Safety Regulations and Appropriate Application:

 

The unit has been designed according to the valid safety regulations.  

Appropriate application is restricted to: 

 

1.

 

Fused battery direct voltage with nominal voltage 12 V or 24 V. 

2.

 

Technically faultless condition. 

3.

 

Installation in a well-ventilated room, protected from rain, humidity, dust, aggressive battery gas, as well as 
in an environment being free from condensation water. 

4.

 

With a rear insulating cover of the display unit. 

 

Never use the unit at locations where the risk of gas or dust explosion exists! 

 

Cables are always to be laid in such a way that damage is excluded. Observe to fasten them tightly.

 

 

Never lay 12 V (24 V) cables and 230 V mains supply cables into the same cable conduit (empty conduit).

 

 

Check live cables or leads periodically for insulation faults, points of break or loosened connections. Occurring 
defects must be remedied immediately.  

 

Always disconnect the power supply to the battery prior to working on the electric system. 

 

The unit is to be disconnected from any connection prior to electrically welding. 

 

If the user is not able to draw from the manual, which characteristic values are valid for a unit or which 
regulations are to be observed, a specialist is to be consulted. 

 

The user/buyer is obliged to observe any construction and safety regulations. 

 

The unit is not equipped with parts, which can be replaced by the user.

  

 

Never use solvents or aggressive household cleaners for cleaning of the display! 

 

The warranty period is 36 months from the purchase date (against presentation of the sales slip or invoice). 

 

The warranty will be void in case of any inappropriate utilisation of the unit, if it is used beyond the technical 
specification, in case of improper operation or external intervention. We do not assume any liability for any 
damage resulting hereof. The liability exclusion is extended to any service being executed by third, which has 
not been ordered by us in writing. Service is to be effected exclusively by VOTRONIC Lauterbach.

 

Содержание Info Panel Pro

Страница 1: ...tion place in the front panel of the furniture should be chosen in such a way that the contrast of the display be not hindered sun light The small mounting depth of only 12 mm of the electronic system allows flush mounting into commercial furniture boards to ensure that an optimum installation place can always be chosen without losing precious storage space The clear opening of the furniture cutou...

Страница 2: ...penditure of force is required We therefore recommend to carefully using pliers for the first insertion Switch Functions Main Switch This switch is used to switch the entire power supply in the camper on or off It is indicated by the red light emitting diode Main Switch The switch is designed for small to medium sized systems which means that the maximum switching current of the board supply shoul...

Страница 3: ...s 12 75 V If the brightness of the light emitting diodes is different the battery voltage tends to the light emitting diode being the brighter one The range of operation of the lead battery 12 V is indicated by the red and green light emitting diodes and it is valid for inferior to normal load current consumption of the battery Green means o k If powerful consumers with high current consumption ar...

Страница 4: ...lay When pressing the key the instantaneous level of the tank will be displayed If they key is pressed again the display is switched off In case of an empty tank the lowest LED is always lighting dimly at least brightness 10 minutes after the last activity the display will be switched off automatically for reasons of power saving Activation of the tank transmitters is effected together with the di...

Страница 5: ...cted to 1 Fused battery direct voltage with nominal voltage 12 V or 24 V 2 Technically faultless condition 3 Installation in a well ventilated room protected from rain humidity dust aggressive battery gas as well as in an environment being free from condensation water 4 With a rear insulating cover of the display unit Never use the unit at locations where the risk of gas or dust explosion exists C...

Страница 6: ... 6 Connection Plan Info Panel Pro Rear View ...

Страница 7: ...iguration of Connections Info Panel Pro Female Connector 6 3 mm yellow 6 3 mm yellow 6 3 mm blue Designation Board Battery Minus Body Ground Board Battery Plus Output Consumers of Board Battery Starter Storage Battery Plus Tank Pulse Fresh Water Tank Pulse Sewage Water Tank Pulse Feces Tank switched for Fresh Water Sewage Water and Feces Tank Pump Plus Battery Protector see Page 3 No 1 2 2a 3 4 Fr...

Страница 8: ...0 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in the household waste The product is RoHS compliant It complies with the directive 2011 65 EU for Reduction of Hazardous Substances in electrical and electronic equipment Delivery Scope 1 Pc Info Panel Pro 2 Pcs Female Connectors 6 3 mm yellow for 4 mm 6 mm 1 Pc Female Connector 6 3 mm blue for 1 mm 2 ...