Votronic 1245 Скачать руководство пользователя страница 4

- 4 - 

Safety Regulations and Appropriate Application: 

The unit has been designed according to the valid safety regulations. 

 

 

Appropriate application is restricted to: 

 

1.

 

Fused battery direct voltage with nominal voltage 12 V or 24 V. 

2.

 

Technically faultless condition. 

3.

 

Installation in a well-ventilated room, protected from rain, humidity, dust, aggressive battery gas, as well as in 
an environment being free from condensation water. 

4.

 

With a rear insulating cover of the display unit. 

 

Never use the unit at locations where the risk of gas or dust explosion exists! 

 

Cables are always to be laid in such a way that damage is excluded. Observe to fasten them tightly.

 

 

Never lay 12 V (24 V) cables and 230 V mains supply cables into the same cable conduit (empty conduit).

 

 

Check live cables or leads periodically for insulation faults, points of break or loosened connections. Occurring 
defects must be remedied immediately.  

 

Always disconnect the power supply to the battery prior to working on the electric system. 

 

The unit is to be disconnected from any connection prior to electrically welding. 

 

If the user is not able to draw from the manual, which characteristic values are valid for a unit or which regulations 
are to be observed, a specialist is to be consulted. 

 

The user/buyer is obliged to observe any construction and safety regulations. 

 

The unit is not equipped with parts, which can be replaced by the user.

  

 

Never use solvents or aggressive household cleaners for cleaning of the display! 

 

The warranty period is 36 months from the purchase date (against presentation of the sales slip or invoice). 

 

The warranty will be void in case of any inappropriate utilisation of the unit, if it is used beyond the technical 
specification, in case of improper operation or external intervention. We do not assume any liability for any 
damage resulting hereof. The liability exclusion is extended to any service being executed by third, which has not 
been ordered by us in writing. Service is to be effected exclusively by VOTRONIC, Lauterbach. 

 

 

Declaration of Conformity: 

In accordance with the provisions of Directives 2014/35/EU, 2014/30/EU, 2009/19/EC, this 
product complies with the following standards or normative documents: 
EN55014-1;  EN55022 B;  EN61000-6-1;  EN61000-4-2;  EN61000-4-3;  EN61000-4-4;   
EN62368-1;  EN50498.

 

 

The product 
must not be 
disposed of in 
the household 
waste. 

 

The product is RoHS compliant. 
It complies with the directive 
2011/65/EU for Reduction of 
Hazardous Substances in electrical 
and electronic equipment. 

 

 
 

Technical Data:

 

Operating Voltage: 

12 V DC (Battery Voltage, Lead / Acid, Gel, AGM Battery)

 

 

 

Operating Voltage Range:  9 V - 16 V DC 

 

 

 Current Consumption: 

1 mA (OFF) - max. 15 mA (Display active) 

 

 

 Weight: 

28 g 

 

 

 Dimensions: 

85 x 47 x 17 mm 

 

 

 

Assembly Dimensions: 

29 x 62 mm 

 

 

 Mounting Depth: 

14 mm 

 
 
 

Delivery Scope: 

-  Duo Storage Battery Tester S

 

 

 

-  4 ea. Fastening Screws 

 

 

-  Installation and Operating Manual 

 

 

-  Drilling Jig 

 
 

Subject to misprints, errors and technical modification without notice. 
All rights reserved, particularly the right of reproduction. Copyright 

 VOTRONIC 07/18. 

Made in Germany by VOTRONIC Electronic-Systeme GmbH & Co. KG, Johann-Friedrich-Diehm-Str. 10, 36341 LAUTERBACH / GERMANY 
Phone: +49 (0)6641 / 91173-0     Fax: +49 (0)6641 / 91173-20    E-mail: [email protected]     Internet: www.votronic.de 

Содержание 1245

Страница 1: ...s the tank displays S the LCD displays S as well as the switch panels and fuse panels S is a useful application The units can be combined perfectly with regard to appearance and their installation is easy see example modular system Installation Choose a well visible and easily accessible location in the living area for installation of the unit The installation place in the front panel of the furni...

Страница 2: ...s jut out laterally The unit is protected from reverse battery and mixed up Lead the cable up to the battery connections By this incorrect measurements due to voltage losses at the power distributors cables etc are avoided Cable Protection Arrange the fuses for protection against short circuits close to the battery Note Amongst others the connections of the panel are marked with numbers The number...

Страница 3: ...rent the battery voltage tends to the light emitting diode being the brighter one The range of operation of the lead battery 12 V is indicated by the red and green light emitting diodes and it is valid for inferior to normal load current consumption of the battery Green means o k If powerful consumers with high current consumption are used such as inverters the battery voltage might drop below 11 ...

Страница 4: ...e purchase date against presentation of the sales slip or invoice The warranty will be void in case of any inappropriate utilisation of the unit if it is used beyond the technical specification in case of improper operation or external intervention We do not assume any liability for any damage resulting hereof The liability exclusion is extended to any service being executed by third which has not...

Отзывы: