Important Safety Instructions

EN_1

1. Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions.

5. Do not use this apparatus near water. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturers 
instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 
has two blades with one wider than the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the points where they exit from the apparatus.

13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus 
has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.

14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,
such as vases shall be placed on the apparatus.

15. 

WARNING:

 

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or

moisture.

16. Installation should be done only by qualified personnel and conform to all local codes.

20. 

CAUTION:

 

These servicing instructions are for use by qualified service personnel only. To

reduce the risk of electric shock do not perform any servicing other than that contained in the
operating instructions unless you are qualified to do so.

Website:www.voscom.com

Website:www.voscom.com

Содержание VOS-2H3G-ADCEMR

Страница 1: ...s 2 Channel 3G SDI 2 Duplex Audio 1 Duplex Data 2 Simplex or 1 Duplex Contact Closure IP Ethernet Installation Manual Fiber Optic Transmission Systems VOSCOM TECHNOLOGIES CO LIMITED WWW VOSCOM COM TM...

Страница 2: ...ed particularly at plugs convenience receptacles and the points where they exit from the apparatus 13 Refer all servicing to qualified service personnel Servicing is required when the apparatus has be...

Страница 3: ...mum Transmission Distance Multi Mode 1310nm 1550nm VOS 2H3G ADCEMR VOS 2H3G ADCEMT The Optical Power Budget data fit Mulit mode 62 5 125 m Single Mode 9 125 m When using 50 125 m multimode fiber subtr...

Страница 4: ...iber Optic Connector support FC PC or ST PC optical connector 1 Website www voscom com Website www voscom com 8 5 PIN Terminal Block CC Connector 2 Simplex or 1 duplex Contact Closure Input Output ON...

Страница 5: ...ber Optic Connector support FC PC or ST PC optical connector 1 Website www voscom com Website www voscom com 8 5 PIN Terminal Block CC Connector 2 Simplex or 1 duplex Contact Closure Input Output ON O...

Страница 6: ...s232 Rs485 Data Input Output Data Connection Input Output Input Output Input Output A B G C D Conect Data Rs485 B Input Output Conect Data Rs232 TXD Input Output 5 Pin Terminal Block A B G C D Conect...

Страница 7: ...2nd Channel Audio Input Receiver Audio 2 Channel Duplex Audio Input Output Website www voscom com Website www voscom com Input 1st Channel Audio Output 2nd Channel Audio Output Input Output Output 5...

Страница 8: ...ntact Closure 2 Channel Simplex CC Output Input 1 Channel CC Input 1 Channel CC Input Input Input Input NOTE the device can support 2 simplex or 1 duplex contact closure but it only can be configurate...

Страница 9: ...ntact Closure 1 Ch Duplex CC Input Output Input 1 Channel CC Output 1 Channel CC Output Input Output Output NOTE the device can support 2 simplex or 1 duplex contact closure but it only can be configu...

Страница 10: ...OFF AC100V 240V POW LOCK A3 B3 G A4 B4 Power Supply Power Supply Display Display 3G SDI Input 3G SDI Input Local Loopbac k Local Loopbac k 1 Channel Duplex RS 232 RS 485 Data 3G HD SDI Source with PTZ...

Страница 11: ...ted to a wall This manual is for the 19inch 1U rack VOS 2H3G ADCET VOS 2H3G ADCER NOTE Before mounting the transmitter receiver please ensure that there is adequate space at both ends for viewing the...

Страница 12: ...ors and associated troubleshooting guidelines Table A Power Links Indicator Status Meaning Possible Cause Corrective Action Video LED VIDEO 1 VIDEO 2 Light Incoming video signal is present on thechann...

Страница 13: ...t Data is not present on the channel No action required Data connection is faulty Check data connections Data communication cable is defective Replace cable The optical signal is not being received Re...

Страница 14: ...acements nonwarranty repairs advance replacements and credit returns To obtain an RMA Download from www voscom com and please complete the RMA as much detail as possible then send the RMA to our custo...

Страница 15: ...rtment will evaluate the returned product to determine whether it is a warranty or non warranty replacement and bill you accordingly We will invoice advance replacements at shipment and credit you upo...

Страница 16: ...document here www voscom com 3 Online Technical Support please E mail support voscom com 4 More detail product information please E mail sales voscom com or contact with our sales staff 5 Return defec...

Страница 17: ...R MOISTURE DO NOT LOOK INTO OPTICAL PORTS WITH POWER ON Headquarters Information Distributor Information VOSCOM TECHNOLOGIES CO LIMITED Hangzhou Zhejiang P R CHINA 310004 Tel 86 571 87389389 Fax 86 57...

Отзывы: