64
14
14
CA 100 ES, 125 ES, 150 Q ES, 150 ES, 160 ES
200 ES, 250 ES, 315 ES
WIRING TO AN EXTERNAL LOW/HIGH SPEED SWITCH
1
2 POLES SWITCH (DPST)
2
3
LOW/HIGH SPEED SWITCH
SPST
DRY CONTACT FOR
ALARM SIGNALLING
(250VAC, max current 3A)
1
L
N
2
3
MIN
MAX
P0
PI
P1 0
S1
S2
PCB
N L
R2
R1
P0 = Potentiometer 0V = GND
PI = Potentiometer Input Signal = 0-10V
P10 = Potentiometer 10V = +10V
S1-S2 = dry contact for MAX/MIN speed
R1-R2 = dry contact for optional Alarm
15
15
CA 100 ES, 125 ES, 150 Q ES, 150 ES, 160 ES
200 ES, 250 ES, 315 ES
1
2 POLES SWITCH (DPST)
2
DRY CONTACT FOR
ALARM SIGNALLING
(250VAC, max current 3A)
1
L
N
2
CONTROL BOX
PCB
N
L
N1
L1
S3
S2
S1
SC
BC
BNO
BNC
P0
PI
P1 0
S1
S2
R2
R1
N L
WIRING TO THE “POTENTI ON/OFF” CONTROL BOX (CODE 12826)
P0 = Potentiometer 0V = GND
PI = Potentiometer Input Signal = 0-10V
P10 = Potentiometer 10V = +10V
S1-S2 = dry contact for MAX/MIN speed
R1-R2 = dry contact for optional Alarm