NOZZLE SELECTION CHART
NOZZLE ORIFICE
1000
1250
1500
1750
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
3250
3500
3750
4000
4500
5000
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
2.0
1.00
1.12
1.22
1.32
1.41
1.45
1.48
1.52
1.55
1.58
1.61
1.64
1.67
1.70
1.73
1.80
1.87
1.94
2.00
2.12
2.24
2.5
1.25
1.40
1.53
1.65
1.77
1.81
1.85
1.90
1.94
1.98
2.02
2.06
2.09
2.13
2.17
2.25
2.34
2.42
2.50
2.65
2.80
3.0
1.50
1.68
1.84
1.98
2.12
2.17
2.22
2.27
2.32
2.37
2.42
2.47
2.51
2.56
2.60
2.70
2.81
2.90
3.00
3.18
3.35
3.5
1.75
1.96
2.14
2.32
2.47
2.54
2.60
2.66
2.71
2.77
2.82
2.88
2.93
2.98
3.03
3.15
3.27
3.39
3.50
3.71
3.91
4.0
2.00
2.24
2.45
2.65
2.83
2.90
2.97
3.04
3.10
3.16
3.22
3.29
3.35
3.41
3.46
3.61
3.74
3.87
4.00
4.24
4.47
4.5
2.25
2.52
2.76
2.98
3.18
3.26
3.34
3.42
3.49
3.56
3.63
3.70
3.76
3.83
3.90
4.06
4.21
4.36
4.50
4.77
5.03
5.0
2.50
2.80
3.06
3.31
3.54
3.63
3.71
3.79
3.87
3.95
4.03
4.11
4.18
4.24
4.33
4.51
4.68
4.84
5.00
5.30
5.59
5.5
2.75
3.07
3.37
3.64
3.89
3.99
4.08
4.17
4.26
4.35
4.43
4.52
4.60
4.68
4.76
4.96
5.14
5.33
5.50
5.83
6.15
6.0
3.00
3.35
3.67
3.97
4.24
4.35
4.45
4.55
4.65
4.74
4.84
4.93
5.02
5.11
5.20
5.41
5.61
5.81
6.00
6.36
6.71
6.5
3.25
3.63
3.98
4.30
4.60
4.71
4.82
4.93
5.03
5.14
5.24
5.34
5.44
5.54
5.63
5.86
6.08
6.29
6.50
6.89
7.27
7.0
3.50
3.91
4.29
4.63
4.95
5.07
5.19
5.31
5.42
5.53
5.64
5.75
5.86
5.96
6.06
6.31
6.55
6.78
7.00
7.42
7.83
7.5
3.75
4.19
4.59
4.96
5.30
5.43
5.56
5.69
5.81
5.93
6.05
6.16
6.27
6.39
6.50
6.76
7.02
7.26
7.50
7.95
8.39
8.0
4.00
4.47
4.90
5.29
5.66
5.80
5.93
6.07
6.20
6.32
6.45
6.57
6.69
6.81
6.93
7.21
7.48
7.75
8.00
8.49
8.94
8.5
4.25
4.75
5.21
5.62
6.01
6.16
6.30
6.44
6.58
6.72
6.85
6.98
7.11
7.24
7.36
7.66
7.95
8.23
8.50
9.02
9.50
9.0
4.50
5.03
5.51
5.95
6.36
6.52
6.67
6.82
6.97
7.12
7.26
7.70
7.53
7.66
7.79
8.11
8.42
8.71
9.00
9.55
10.06
9.5
4.75
5.31
5.82
6.28
6.72
6.89
7.05
7.22
7.36
7.51
7.66
7.81
7.95
8.09
8.23
8.56
8.89
9.20
9.50
10.08
10.62
10.0
5.00
5.59
6.12
6.61
7.07
7.25
7.42
7.59
7.75
7.91
8.06
8.22
8.37
8.52
8.66
9.01
9.35
9.68
10.00
10.61
11.18
11.0
5.50
6.15
6.74
7.28
7.78
7.97
8.16
8.34
8.52
8.70
8.87
9.04
9.20
9.37
9.53
9.92
10.29
10.65
11.00
11.67
12.30
12.0
6.00
6.71
7.35
7.94
8.49
8.70
8.90
9.10
9.30
9.49
9.67
9.86
10.04
10.22
10.39
10.82
11.22
11.62
12.00
12.73
13.42
12.5
6.25
6.99
7.65
8.27
8.84
9.06
9.27
9.48
9.68
9.88
10.08
10.27
10.46
10.65
10.83
11.27
11.69
12.10
12.50
13.26
13.98
13.0
6.50
7.27
7.96
8.60
9.19
9.42
9.64
9.86
10.07
10.28
10.48
10.68
10.88
11.07
11.26
11.72
12.16
12.59
13.00
13.79
14.53
15.0
7.50
8.39
9.19
9.92
10.61
10.87
11.12
11.37
11.62
11.86
12.09
12.32
12.55
12.77
12.99
13.52
14.03
14.52
15.00
15.91
16.77
20.0
10.00
11.18
12.25
13.23
14.14
14.49
14.83
15.17
15.49
15.81
16.12
16.43
16.73
17.03
17.32
18.03
18.71
19.36
20.00
21.21
22.36
GPM
This pump is designed for pumping
non-flamable or non-combustible
fluids. The pump is intended to
pump clean filtered water.
Modifictaions to the manufacturer
design is not recommended.
Do not operate in an enclosed area
or around explosive materials. Al-
ways make sure you have adequate
ventillation in your work environ-
ment.
Always wear the proper safety
equipment when operating this
pump.
Do not allow children to operate
this pump.
Be careful with where you point the
high-pressure discharge. Never
point it at a person or animals body
or body part.
Do not exceed pumps specifica
-
tions in shaft speed or discharge
pressure.
Maximum temperature of pumped
water should not exceed 140°F.
General Safety Information
Winter/Long Term Storage
1. Drain all of the water from the
pump.
2. Screw in bottle of Vortex Pump
Saver to the garden hose inlet and
open up the valve on the cap of the
bottle.
3. Make sure your pressure washer
on off switch is in the off position and
slowly pull on the pull start rope while
squeezing the pump saver bottle to
cycle the contents through the pump.
4. When you see pump saver come
out of the outlet you can stop cycling
the pump. Close the valve on the
bottle cap and remove it from your
pump.
5. Before your next use make sure
you flush the pump by running fresh
water through it.