background image

LED Illumination

High efficiency LED (Light Emitting Diodes) rated at 

50,000 hours operating life.

5,700 Degrees Kelvin Colour  

Temperature(Daylight).

Caution: Hot surface. Avoid direct skin contact 

with aluminium heat sink during extended periods 

of use.

Caution: Do not look directly into the LED Light.

Dimmable Illumination

The dimmer switch is located on the cable near the 

Power Pack Plug. (Refer to Figure 1)

The dimmer function provides 8 levels of  

illumination with “H” being the highest .

Dimming

Press the “

+

” or “

-

” button on the 

dimmer switch to select the preferred level of 

illumination.   

ON/OFF function

: Click & hold either button on 

the dimmer switch for 2 seconds to turn illumination 

“on” or “off” at the selected level.

Magnification

The VorOtek M Scope is supplied with three 

interchangeable plate magnifiers  (2, 4 or 6 diopter)

Power Pack

Power Packs are Lithium Ion: 11.1 Volts, 2,900 

mAh.

The Power Pack delivers 7hrs to >20hrs “on time” 

depending on illumination level.

Caution: Only use approved Power Packs 

supplied by VorOtek

.

The Power Pack features short circuit protection 

and charging control circuitry.

Two position switch - ON/OFF.

Designed to be worn in the breast pocket or to 

be clipped to a belt. It can also be clipped to the 

back of a surgical gown.

Caution: Do not expose the Power Pack to heat, 

fire or mechanical shock

Caution: Do not open or dismantle the Power 

Pack.

Caution: Only use approved Power Packs 

supplied by VorOtek.

Charger - Charging Power Pack

Connect Power Pack to Charger.

The Power Pack can be charged in either the ON 

or OFF position.

RED INDICATORS – Charging (takes up to 5 

hours).

GREEN INDICATORS – 100% Charged.

Charging is best done overnight, frequently and 

before the Power Pack runs flat.

Caution: Use the supplied 12.6V Charger only.

Caution: Do not attempt to operate the Charger 

if the cord and/or plug appear to be damaged.

Caution: Do not use Charger in the patient 

vicinity.

Set Up

Attaching Plate Magnifiers

To attach a plate magnifier (2, 4 or 6 diopter), 

insert one end of the plate into  one end of the 

mounting bracket. Then gently push the other 

end  of the  mounting bracket out wards and 

insert the other end of the plate. Ensure the 

curved side of the plate is facing the patient & 

the  flat edge  of the plate is facing down. 

Removing Plate Magnifiers

To remove a plate magnifier gently push one side 

of the mounting backed outwards and remove 

the plate. 

NOTE: The flat surface of the magnifier should face 

the user

Tilt Adjustment – HeadBand Model

If the magnifiers are tilted, adjust the HeadBand 

position until level.

Tilt Adjustment –SpecFrame Model

If the magnifiers are tilted, adjust the nose pads & 

temple tips/arms on the SpecFrame until level.

Height Adjustment - HeadBand Model

The height of the illumination system is adjusted by 

moving the HeadBand up or down on the forehead.

Height Adjustment -SpecFrame Model

The height of the illumination system is adjusted  by 

moving the system up or down on the  SpecFrame 

bracket:

Loosen the screw that connects the  illumination 

system to the SpecFrame bracket by 1 turn and 

adjust the height.

Do not leave screw loose, always re-tighten.

HeadBand Bracket Adjustment 

The HeadBand mounting bracket has 2 adjustable 

links allowing separate adjustment of the angle of 

declination and forward positioning of the 

magnifiers / illumination system.

SpecFrame Toggle

The toggle on the cable lead should be used for all 

lengthy procedures, e.g. Operating to:

Prevent SpecFrame sliding down the nose when 

head is tilted down.

Take pressure off the nose.

Working with Corrective Lenses

Corrective Lenses can be fitted to the SpecFrame of 

the M Scope by an Optometrist.

There is no need to unscrew the illumination 

system or dismantle the M Scope in any way, 

other than the frame screws for the lenses.

Reading Lenses (used for close work)

Should be fitted to the SpecFrame Model.

The HeadBand model should be used over the 

individuals own corrective spectacles.

When reading lenses are installed and used, the 

working distance becomes closer.

Bifocal Lenses

Can be fitted effectively, so long as the plate 

magnifiers sit in front of the reading section and 

below the distance section.

To achieve this, the reading section must be 

larger (i.e. lower two thirds) and the distance 

section must be smaller (i.e. upper one third 

only).

The height of the nose bridge may need to be 

adjusted to sit the SpecFrame higher on the face. 

This extra frame height allows lower positioning 

of the plate magnifiers so that they are in front of 

the reading section.

Alternative nose bridges are available from most 

optometrists

Multifocal Lenses

Are best avoided because it is difficult to achieve 

sharp focus.

Troubleshooting

LED illumination cuts out and resets 

repeatedly

The LED illumination does not fade, but the 

protective circuit breaker keeps switching off (and 

resetting) when the Power Pack requires 

recharging. See section on ‘Charger’.

LED’s rarely need replacing, but if this is necessary 

it must be done by VorOtek.

Power Pack will not charge

See section on ‘Charger’. 

SpecFrame damage

Most problems can be dealt with by an 

optometrist e.g. missing screws, new nose pads 

and bent frames

For SpecFrame replacement contact VorOtek. 

For all other questions contact VorOtek.

Technical Manual

SCOPE

M

Figure 1. Dimmer Switch 

LCD Display 

Increase Illumination

Decrease Illumination