background image

CL3-0612 R-, V00

MODEL ELEMENT S

vornado.com

Содержание ELEMENT S

Страница 1: ...MODEL ELEMENT S ...

Страница 2: ...1 English vornado com 800 234 0604 help vornado com we expect this product to be PERFECT if it s not WE will make it right ...

Страница 3: ...2 English Important Safety Instructions 3 Getting Started 6 Features 8 Controls 10 How to Use 12 Cleaning 16 Mineral Build Up 21 Troubleshooting 23 Warranty 26 CONTENTS ...

Страница 4: ...nd anyone with reduced physical sensory or mental capabilities Children should be supervised to ensure that they do not play with the appliance its parts and packaging material INSTALLATION WARNING To reduce risk of fire electrical shock and injury to persons observe the following No part of this product the appliance power cord plug packaging etc should be placed near furnaces fireplaces stoves o...

Страница 5: ...input or output opening as this may cause risk of electric shock or fire or damage the product A loose fit between wall outlet receptacle and plug may cause overheating and distortion of the plug Discontinue use of the product in this outlet Contact a qualified electrician to replace loose or worn outlets This appliance has a polarized plug one blade is wider than the other To reduce the risk of e...

Страница 6: ...n the tank for longer than 8 hours thoroughly clean and disinfect the unit as described in the section of this Owner s Guide referenced as CLEANING DISPOSAL WARNING To reduce waste and environmental harm observe the following PACKAGE RECYCLING The packaging protects the appliance from transport damage The packaging materials are selected from the point of view of their environmental friendliness a...

Страница 7: ... avoid overfilling the base remove the water tank before the power head to avoid water displacement GETTING STARTED CHECK FOR LEAKS Damage due to shipping may cause leaks in base or water tank A visual inspection may not reveal hairline fractures 1 Place humidifier on a water resistant surface 2 Fill water tank with water to inspect for leaks 3 Pour several cups of water into base to inspect for l...

Страница 8: ...ed before you replace it in the humidifier Ensure gasket the rubber ring around the Water Tank is properly positioned Insert the Cap into the grooves of the tank and turn clockwise until tightened When Cap is fully tightened the arrows on the tank will align with the indicator lines on the Cap ...

Страница 9: ...carry fill install clean and view water level 0 75 gallon capacity OUTLET GRILL Emits humidity throughout the whole room POWER HEAD CARRY HANDLES Integrated handles on sides of base for lifting and carrying BASE Durable and easy to clean FEATURES 1 2 3 4 5 ...

Страница 10: ...9 English 1 5 4 2 3 ...

Страница 11: ...Y Control humidity level at 30 70 STEAM TEMPERATURE SETTINGS Customize your steam experience with cool warm or hot steam settings DIGITAL DISPLAY Easy to use touch controls STEAM SETTING INDICATOR Color indicator illuminates steam setting Cool steam purple warm steam pink and hot steam orange red 1 2 3 4 5 ...

Страница 12: ...11 English 1 5 3 4 2 ...

Страница 13: ...y will illuminate white 2 Set humidity level by touching The humidity settings will increase in increments of 5 Once set humidity is reached Element will turn off until the humidity level drops below the selected setting The humidifier will evaporate 4 gallons of water 10 in 24 hours of continuous operation This assumes room conditions of 70º F and 30 relative humidity ...

Страница 14: ...epending on selected steam setting the temperature of the mist at the outlet grill may be hot WARNING After using the humidifier if you disassemble the unit for any reason the boil chamber will contain hot water The heat element will also be extremely HOT Cool down at least 30 minutes before touching these components Color indicator will illuminate ...

Страница 15: ...be able to change the settings or power off If you try to change settings while locked the control panel LED s will flash 3 times and attention code LC will also flash When the humidifier is powered off you may still use the control lock feature Follow the instructions above to lock and unlock The control panel will flash LC 1 time to indicate the controls are locked 2 times when unlocked and 3 ti...

Страница 16: ...nk is refilled Once water is added CH code will clear after a short period of time Unit does not need to be powered on as it will automatically resume operation once water is added Note When tank is out of water there will be no visible steam CL When the heat element has accumulated mineral scale and cleaning is needed a CL cleaning notification code will flash for 5 seconds on the control panel e...

Страница 17: ...mental factors It is recommended to thoroughly clean the unit once a week or when Attention Code CL appears on control panel HEAT ELEMENT Heats water in boil chamber to generate steam HEAT ELEMENT COVER Silicone cover seals steam compartment and provides protection for heat element BOIL CHAMBER Silicone chamber holds water heated by heat element RESERVOIR Silicone reservoir feeds water from water ...

Страница 18: ...ish 1 2 3 4 GENERAL CLEANING To clean the exterior of the humidifier wipe down with a soft damp cloth Do not submerge power head in water Clean the grill with a soft damp cloth or with a can of compressed air ...

Страница 19: ...re not dishwasher safe Do not use gasoline thinners solvents or other chemicals for cleaning The silicone parts are dishwasher safe place on the top rack of dishwasher only Warm water and a mild detergent may also be used for cleaning these parts ...

Страница 20: ... located on the right side of the housing where it meets the base Remove all silicone parts WARNING Do not grasp outlet grill while removing power head it may be hot 3 Clean base and silicone parts with warm water and a mild detergent Rinse and dry 4 Reassemble humidifier Ensure the silicone parts are back in place WARNING Do not run humidifier without the silicone parts Position power head so it ...

Страница 21: ...occasion the water tank may need to be gently wiped down or cleaned to remove build up of impurities Clean with a mild detergent and cool water If the humidifier is turned off with water in base for 8 hours or longer or if humidifier is not cleaned as recommended you may experience some growth of algae or bacteria These microorganisms may become airborne ...

Страница 22: ...eaning heat element Do not allow heat element to touch other objects as it cools REMOVE MINERAL BUILD UP The Element Steam Humidifier includes a packet of Vornado Cleaner Descaler placed inside of the owner s guide Consisting of citric acid this agent is used to loosen and remove mineral build up on the heat element It is easy to use and safe for all Vornado Steam Humidifiers 1 Turn off humidifier...

Страница 23: ...onger depending on amount of build up You may scrub the heat element with a soft bristle brush as particles begin to loosen Avoid hard brushes or steel wool as they can damage the heat element 5 Once clean thoroughly rinse base silicone parts and heat element with cool tap water to ensure all residue is gone before using NOTE Undiluted white vinegar may also be used for cleaning the heat element h...

Страница 24: ...ting on a metal cabinet or surface interference can occur with the permanently affixed magnet located on the base Do not place unit on metal surfaces during operation This is normal and is power being provided to the unit This is normal Water is being dispensed into base You may periodically see bubbles in the tank which is normal This is the water tank feeding water from the reservoir to the boil...

Страница 25: ...hot steam setting for maximum humidity output The water tank has run out of water and CH code is flashing on control panel Refill tank with clean cool water Unit s internal thermostat is turning heat element off and on cycling to ensure proper operating conditions Cycling can occur if heat element needs cleaning The heat element may turn off for approximately 30 45 seconds before turning back on W...

Страница 26: ...K Power head is not attached to the base does not have proper power connection See HOW TO USE ATTENTION CODES When the water tank runs out of water CH code will flash on the control panel until the tank is refilled Once water is added CH code clears and unit continues normal operation See HOW TO USE ATTENTION CODES When the heat element has accumulated mineral scale and cleaning is needed CL code ...

Страница 27: ...modification repair by unauthorized repair center or use of non approved replacement parts is not recommended and any consequences will not be covered by support services or product warranties The product warranty will be honored only on models that are being used in the country intended REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER VORNADO SHALL NOT...

Страница 28: ...CL3 0612 R V00 vornado com ...

Отзывы: