10
Configuration shortcut (key1) as hot key and setup a number, then press shortcut keys can call the
configured number.
3. End call
Enable Release key hang up to end call.
4. Call record
The device provides 900 call records, when the storage space is exhausted, will cover the first call
records. When the device is powered down or reboot, call records will be removed.
You can view the three call records in the Webpage (Door phone/Door log)
5. Open the door operation
Through the following seven ways to open the door:
1) On the keyboard input password to open the door.
2) Access to call the owner; enter the remote to open the door by the owner password to open the
door.
3) Owner/call access control of other equipment and enter the access code to open the door. (access
code to be included in the list to access configuration, and enable for remote calls to open the
door )
4) Through the RFID Cards to open the door.
5) By means of indoor switch to open the door.
6) Private access code to open the door.
Enable for local authentication, and set private access code. Under the standby directly input the
access code to open the door.
7) Active URL control command to open the door.
URL is “http://host/cgi-bin/ConfigManApp.com?key=F_LOCK&code=openCode”, “openCode” is to
remote open the door code
Access code input correct prompt sowing sirens prompt access control and the remote user,
input error by short low frequency chirp.
Password successfully by high-frequency sirens sound prompt, input error is short by high
frequency chirp.
When the door opened by playing sirens sound prompt.
D. Page settings
1. Browser configuration