5. PRACTICAL USE 

 
 

DRILLING I NSTRUMENT MOUNTING 

 
 
 
 
 
 
 

DRILLING THE HOLES 

 

  

 

 

 

 

 

ADJUSTING THE DEPTH OF DRILLING HOLE 

  

 

 

  

 

 

 

 

 
 

REGULATION  OF DRILLING INSTRUMENT REVOLUTION 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
Before      mounting      the      drilling  instrument  make  sure 
that mains supply switch of apparatus (1) is switched off. 

Loose the collet with the help of wrenches sizes 

17

   and 

19

  and  put  the  drilling  instrument  through  the  hole  of 

working table in the collet and tighten. 
 
 
 
Put the plaster model on the working table as holding it 
up with hands on the two sides. 

Using the laser  marker locate the position for drilling by 
view opposite to drilling. 

Press the model to the working table till stay. The motor 
will  switch  on  automatically  and  will  stop  at  returning 
table in its initial stage. 

 

 
Drill a hole in waste plaster model. 

Check the depth of drilled hole by test with pin from pin 
system of your choice. 

If  there  is  insufficient  depth  correct the  movement  of  
working  table  by  turning  regulating  screw  of 
anticlockwise.  Repeat  actions  to  achieve  the  desired 
result. 

If the depth is deeper than the necessary one, correct the 
movement  of  working  table  by  turning  the  regulating 
screw  clockwise.  Repeat  actions  to  achieve  the  desired 
result. 

 

 
Through  the  potenciometer  (2)  revolutions  of  drilling 
instruments  can  be  changed  depending  the  solidity  and  
humidity of used moulding plaster, so that the drilling to 
be  done  maximum  rapidly  and  not  to  impede  working 
motor. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание PinPrecise PP100

Страница 1: ...PinPrecise PP100 en v1 1 Drilling Machine PinPrecise PP100 USER MANUAL ...

Страница 2: ...T 4 INSTALLATION AND INITIAL START UP 5 PRACTICAL USE DRILLING I NSTRUMENT MOUNTING DRILLING THE HOLES ADJUSTING THE DEPTH OF DRILLING HOLE REGULATION OF DRILLING INSTRUMENT REVOLUTION 6 TECHNICAL DATA 7 MAINTENANCE 8 DUST CONTAINER CLEANING 9 SCOPE OF DELIVERY WARRANTY 3 4 5 6 7 7 7 7 7 8 9 9 9 ...

Страница 3: ...r closest assistant However inappropriate use may damage the equipment and be harmful to personnel Please observe the relevant safety instructions and read the Operating Instructions carefully We wish you pleasant and fruitful work with this machine SYMBOLS This symbol indicates that there is high dangerous tension under the bonnet which it is put on This symbol indicates that the machine complies...

Страница 4: ...ice the notices and stickers must be kept in good condition so that they are easily readable they should not be removed the machine must not function in case of being damaged and in position to injure the staff or a third person keep the power cable out of heat oil and coarse objects do not catch the device by the cable when you move it switch off the device and pull out the plug of the feeder cab...

Страница 5: ...e is used for precise drilling the pins in plaster models It is designed to work in dental laboratories 1 Main Switch 2 Potentiometer 3 Regulating Screw 4 Laser Module 5 Working Table 6 Gap for the working instrument 7 Hole for dust monitoring FUSE 1 2 3 6 7 5 4 ...

Страница 6: ...IONS Carefully remove modules from packages Make sure that the mains voltage is 230V and the contact is reliably grounded Place the device so that the plug is accessible Avoid positioning the apparatus near heat sources Plug the power cord into an electrical outlet 230V 50 60Hz ...

Страница 7: ...ress the model to the working table till stay The motor will switch on automatically and will stop at returning table in its initial stage Drill a hole in waste plaster model Check the depth of drilled hole by test with pin from pin system of your choice If there is insufficient depth correct the movement of working table by turning regulating screw of anticlockwise Repeat actions to achieve the d...

Страница 8: ... Length 8 3 Height 9 Model Weight 10 Working temperature 11 Level of environment pollution 12 The device is designed for usage in normal dental premises up to 2000 m altitude above sea level 13 The maximum relative humidity of the air must be 80 for temperatures up to 31 С decreasing lineally to 50 relative humidity for temperature 40 С 230 V 10 50 60Hz max 40 W ІІ 2500 3500 rpm 0 7 mm 3 mm 3А 160...

Страница 9: ...w After work clean the dust container Before container cleaning make sure that the electric supply of device is switch off It is visible by lack of laser beam of light laser marker Through the wooden peg and brush clean the hole of working table where the drilling instrument passes Release the container by turning the pressing plate situated on the back of working table Remove the dust container p...

Страница 10: ...PRECISE PP100 WARRANTY SHEET VOP Ltd warrants the consumer for proper operation of all parts and materials in this product during a period of 12 months since the day of its purchase During this period VOP Ltd or its authorized persons will repair on its own account all defects which have occur during the normal operation of the machine Defects caused by improper transportation storage and manipula...

Отзывы: