![Vonsch Quatrofrem Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/vonsch/quatrofrem-series/quatrofrem-series_configuration-and-diagnostics_1049784034.webp)
UNIFREM v.3.41x
10 May 2017
Page 34 from 180
A sample disley
Description
E43-Reserved
Reserved
E44-Reserved
Reserved
E45-Reserved
Reserved
E46-Reserved
Reserved
E47-BM blocking
Blocking the switching pulses of BM from the source BM blocking [1204] (page 73).
This fault can be turned off by parameter BM blocking fault [1205] (page 74).
E48-Reserved
Reserved
E49-IGBT
Module
overheating
IGBT is operated at very low voltage Vdc, high frequency of PWM switching or at
currents that are not approved by the manufacturer IGBT module. Dor the duration
of this fault, the value of the maximum IGBT current is displayed in FAULTS
window.
E50-Current
controllers instability
Instable or detuned current controllers. Please, look to Manual for vector control
setting.
E51-Vector
control
instability
Instability or loss of orientation of vector control. Please, look to Manual for vector
control setting.
E52-End of the trial
period.
The trial period has expired. The motor operation is locked, please contact the
supplier of frequency converter or device in which the converter is used, and ask for
the conditions for termination of trial operation.
E53-Identification fault
Incorrect result of the motor parameters identification. Please, look to Manual for
vector control setting. For the duration of the fault, the cause of the fault
Identification fault [1093] (page 68) is displayed in FAULTS window.
E54-ARC fault
ARC fault. Please, check the ARC module connection and the connection cable
between the module and the resolver. For the duration of the fault, the value of
Status RM_ARC [292] (page 20) is displayed in FAULTS window.
E55-Rectifier
fault
(VDC)
High value of first or second harmonic in the DC bus voltage.
E56-RM-SERVO fault
Fault of the RM-SERVO extension module or the absolute encoder.
E57-Current
measurement fault /
Disconnected motor
Current measurement failure or disconnected motor.
E58-SMPM
control
fault
Incorrect value of Rotor pole position SMPM [1609] (page 46), or Pole pairs [1613]
(page 44).
E59-Incorrect
IRC/ARC direction
Change the direction of feedback sensor (IRC or ARC), set by Speed source [1000]
(page 58). Evaluation of this fault can be disabled by Encoder fault mode [535]
(page 109).
E60-High
IRC/ARC
freq.
Frequency of IRC / ARC feedback greater than the value set in High freq. encoder
[1612] (page 109). Evaluation of this fault can be disabled by Encoder fault mode
[535] (page 109).