Name [ID]
Description
Def.
Flux PM [1185]
Permanent magnet flux of SMPM [Wb].
0,100 Wb
0,000 Wb ÷ 5,000
Wb
Rotor
pole
position
SMPM
[1609]
Rotor pole position at zero electrical angle in degrees.
0,000
-
360,000
÷
360,000
Mag.
curve
[1169]
Activation of motor magnetization curve mode.
Turned off
Turned off
Parameter Mutual inductance [441] (page 45) is considered to be constant.
Turned on
Parameter Mutual inductance [441] (page 45) is calculated from the magnetization curve
and can be different under different values of magnetic flux.
Current dependent
Parameter Mutual inductance [441] (page 45) is calculated from the magnetization curve
and can be different under different values of stator current.
MAG. CURVE
Group of parameters number [1158]
Settings of the magnetization curve points.
MENU \ SETTINGS \ MOTOR \ SPECIAL PARAMETERS OF THE MOTOR \ MAG. CURVE
Name [ID]
Description
Def.
M.C: Flux 1 [1159]
Flux value of point 1.
1,000
Wb
0,000
Wb
÷
1000,000 Wb
M.C: Flux 2 [1160]
Flux value of point 2.
1,000
Wb
0,000
Wb
÷
1000,000 Wb
M.C: Flux 3 [1161]
Flux value of point 3.
1,000
Wb
0,000
Wb
÷
1000,000 Wb
M.C: Flux 4 [1162]
Flux value of point 4.
1,000
Wb
0,000
Wb
÷
1000,000 Wb
M.C: Flux 5 [1163]
Flux value of point 5.
1,000
Wb
0,000
Wb
÷
1000,000 Wb
M.C: Current 1
[1164]
Magnetization current value of point 1.
1,000 A
0,000 A ÷ 1000,000
A
M.C: Current 2
[1165]
Magnetization current value of point 2.
1,000 A
0,000 A ÷ 1000,000
A
M.C: Current 3
[1166]
Magnetization current value of point 3.
1,000 A
0,000 A ÷ 1000,000
A
M.C: Current 4
[1167]
Magnetization current value of point 4.
1,000 A