![Vonsch Quatrofrem Series Скачать руководство пользователя страница 117](http://html1.mh-extra.com/html/vonsch/quatrofrem-series/quatrofrem-series_configuration-and-diagnostics_1049784117.webp)
UNIFREM v.3.41x
10 May 2017
Page 117 from 180
Name [ID]
Description
Def.
Dig.
3
[1584]
The magnitude of 10 that determines the last transferred digit from the left. (..., 1
tens, 0 ones, -1 tenths, ..).
-
Look choises of parameter's Dig. 1 [1582] (page 116)
Dig.
4
[1585]
The magnitude of 10 that determines the last transferred digit from the left. (..., 1
tens, 0 ones, -1 tenths, ..).
-
Look choises of parameter's Dig. 1 [1582] (page 116)
7.11 PAR. SETS
Group of parameters number [206]
Selecting a set of parameters for the converter operation.
MENU \ SETTINGS \ PAR. SETS
Name [ID]
Description
Def.
Set switching
[657]
Setting the way of switching between the sets.
Combined
Combined
Only the first 2 bits of the binary switch are used. Output set corresponds to the binary
combination of these bits. If no bits are active, the 1st set is active. If only 1 bit is active, the
2nd set is active. and so on.
Single
Every single bit of the binary switch represents one set (bit 1 represents set 2). If more
switches are active, the set with the higher sequence number is active. If no binary switch is
active, the 1st set is active.
Parameter
It is possible to set the active set using the Active set [205] (page 117) parameter.
Active
set
[205]
Switches the active set of parameters, from which the converter will take its
configuration.
Set 1
Set 1
Converter will take its configuration from 1st set of parameters.
Set 2
Converter will take its configuration from 2nd set of parameters.
Set 3
Converter will take its configuration from 3rd set of parameters.
Set 4
Converter will take its configuration from 4th set of parameters.
Switch while
run [1490]
Enabling or disabling of set switching during motor operation.
Enabled
Disabled
Sets can be switched only when motor is not running.
Enabled
Sets can be switched even when motor is running.
7.11.1 SET SWITCH
Group of parameters number [222]
Binary set switch setting.
MENU \ SETTINGS \ PAR. SETS \ SET SWITCH
Name [ID]
Description
Def.
Bit1 set source
[641]
Setting the 1st bit of the set switch. Its function depends on the Set switching [657]
(page 117) parameter setting.
None
Look choises of parameter's Quick stop source. [986] (page 49)
Bit2 set source
[642]
Setting the 2nd bit of the set switch. Its function depends on the Set switching [657]
(page 117) parameter setting.
None
Look choises of parameter's Quick stop source. [986] (page 49)
Bit3 set source
[643]
Setting the 3rd bit of the set switch. Its function depends on the Set switching [657]
(page 117) parameter setting.
None
Look choises of parameter's Quick stop source. [986] (page 49)
SPECIAL SETTING
Group of parameters number [224]
Special functions setting for the set switches.
MENU \ SETTINGS \ PAR. SETS \ SET SWITCH \ SPECIAL SETTING
Name [ID]
Description
Def.