Recessed Exit Device

QEL94/9547

Installation Instructions

© Allegion 2018

Printed in U.S.A.

24158859 Rev. 10/18-c

Customer Service

1-877-671-7011

www.allegion.com/us

Index

Devices covered by these instructions:

QEL94/9547/48 Concealed Vertical Rod Device (Panic and Fire)
QEL94/9547-LBR Concealed Vertical Rod Device (Fire)

Read All Warnings
Before Starting Installation!

Install in accordance with instructions or 

device will not function.

 

 

WARNING

For less bottom rod (LBR) devices, do not 

cover the door gap at the auxiliary fire latch 

with a door edge guard or similar product. 

If edge guard is installed, remove it. 

CAUTION

•  Warnings .......................... ..........  1
•  Parts ...........................................  2
•  General Information ....................  3
•  Specifications .............................  3
•  Tools Needed .............................  3
•  Set Handing ...............................  3
•  Installation ..................................  4

FOR DEVICES SOLD PRIOR TO DEC. 2014

Содержание QEL94/9547 Series

Страница 1: ...e QEL94 9547 LBR Concealed Vertical Rod Device Fire Read All Warnings Before Starting Installation Install in accordance with instructions or device will not function WARNING For less bottom rod LBR devices do not cover the door gap at the auxiliary fire latch with a door edge guard or similar product If edge guard is installed remove it CAUTION Warnings 1 Parts 2 General Information 3 Specificati...

Страница 2: ... PARTS Ratchet release assembly Soffit strike Top latch assembly Top rod assembly QEL motor QEL cable End cap Dogging key panic devices only End cap Bottom rod assembly Bottom latch assembly Sill strike Device ...

Страница 3: ...e being used Before starting installation review Warnings Parts Specifications and Tools Needed Mechanical Vertical rods adjustable for doors 6 8 to 8 tall Rods for 10 doors are available upon request Pushpad projection depressed 1 to 1 Electrical Load Voltage 1 4 A inrush 0 5 sec Current 0 14 A holding 2 0 A calibrate 3 sec one time These are the tools needed for installing a QEL94 9547 into a fa...

Страница 4: ... See trim installation instructions for hole sizes and locations a Determine stop height Figure 2 1 then mark center of hole on device side of door Figure 2 2 b Drill a diameter hole where marked through device side of door only Latch side Hinge side for stop height for stop height for stop height Latch Stop height LHR shown RHR opposite Side opposite hinges dia 2 Top of door Figure 2 1 Figure 2 2...

Страница 5: ...ing crimp connectors Unused wires should be insulated separately The latch bolt monitor switch is activated whenever the latch bolt is retracted The switch function is shown with the latchbolt extended and the touchbar not depressed NOTE Disconnect power before wiring LX switch WARNING Switch Blue Red Yellow NC NO Figure 3 1 Figure 3 2 Field wiring Power transfer Von Duprin EPT10 shown or EPT2 can...

Страница 6: ...Figure 4 2 and trim installation instructions PS900 Series Power Supply with 900 2RS 900 4R or 900 4RL Option Board 18 AWG required Maximum distance 200 QEL INPACT Exit Device Electric Power Transfer Voltage 1 4 A inrush 0 5 sec Current 0 14 A holding 2 0 A calibrate 3 sec one time QEL Electrical Load QEL Cable pan head machine screws quantity 4 pan head machine screws quantity 2 Figure 4 1 Figure...

Страница 7: ...rep at door top Figure 6 3 and attach rod to center case Figure 6 4 d Fasten latch to door with supplied screws Figure 6 5 9 8 7 6 5 4 B 3 2 10 A 1 Line up with one of these holes Install rivet For door heights between those shown on the chart use the next door height up For example for a 6 11 door use 7 on the chart 6 8 6 10 7 0 7 2 7 4 7 6 7 8 7 10 8 0 8 2 8 4 1 1 2 3 4 5 6 7 8 9 10 B A A A A A ...

Страница 8: ...LATCH SKIP THIS STEP FOR LBR DEVICES 8 INSTALL 338 SOFFIT STRIKE a Repeat steps 6a through 6d for bottom rod and latch Use hole 8 for most applications Approximate rod length is 34 b Press pushpad to retract latches c Hang door ...

Страница 9: ...9 of 16 9 INSTALL SILL STRIKE OR THRESHOLD SKIP THIS STEP FOR LBR 25 drill and 10 24 tap 2 places 10 INSTALL RATCHET RELEASE ASSEMBLY Strike Carpet ...

Страница 10: ...st the top rod so it is shorter f Open door and release latches by inserting a Phillips head screwdriver into the ratchet release plunger hole Check top latch deadlocking Top latch should not retract when pressed down If top latch bolt does not stay fully retracted shorten top rod Figure 11 2 and retest If top latch bolt does not fully extend or deadlock lengthen top rod Figure 11 2 and retest If ...

Страница 11: ...s behind legs of center case connector Install screw with hex key 13 INSTALL RETAINER CLIPS ON TOP AND BOTTOM RODS AT CENTER CASE a Fully depress pushpad and release Top latch should be in retracted position b Adjust bottom rod length by rotating rod so latch clears floor when door is open Lengthen rod Shorten rod ...

Страница 12: ...Option Board Mounting PS902 PS904 PS914 PS906 1 1 2 2 3 1 Locations Gray Plug Option Board Cable into any Available Option Connector 3 The QEL is compatible with an existing 900 2Q board if currently installed 5 Latchbolt retraction of 2 sequenced QEL s requires more than 1 second to complete 6 For double door QEL applications with auto operators it is recommended to use a PS904 906 or 914 power s...

Страница 13: ...AC 50 60Hz SC I1 01 I2 02 GND Note Fail secure output only allowed if approved by Authority Having Jurisdiction Individual Mode Typical Wiring Input I1 will activate output 1 Input I2 will activate output 2 QEL Device 2 not polarized Access Control for Device 2 EPT 2 10 QEL Device 1 not polarized Access Control for Device 1 EPT 2 10 SC I1 01 I2 02 GND 900 2RS 120 240 VAC 50 60Hz For other option b...

Страница 14: ... input and verify all QEL devices operate properly NOTE During the first activation each device will perform a one time self calibration which is normal For best results power each device separately so that the calibration cycles do not overlap b If any device does not operate properly see step 19 for troubleshooting ...

Страница 15: ...to the QEL is being controlled by an access control system with momentary unlock calibrate as follows 1 Open door completely if using auto operator 2 Press and hold the QEL pushbutton 3 Activate the access control input to unlock the QEL 4 Immediately after the QEL LED turns on green release the QEL pushbutton 5 The QEL will calibrate this will look like a fast then a slow pull 6 Reapply power to ...

Страница 16: ...LL END CAPS 21 INSTALL AUXILIARY FIRE LATCH LBR DEVICES ONLY See installation instructions packaged with auxiliary fire latch kit End cap End cap NOTE Make sure pushpad is in outward position before installing end caps ...