![Von Duprin 98 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/von-duprin/98/98_installation-instructions-manual_1049105009.webp)
FAX version 911373_00(1) Page 9 of 9
9
2
Tape and mark area being cut.
CUT DEVICE
Cut device
square
and remove all
burrs
1-1/2 minimum clearance
(with endcap removed)
Device aligned
with mounting
holes
3
Cut device square.
NOTE: Device must
be cut
square
for
proper end cap fit
4
Slide anti-rattle clip into device
.
Tape
Cover plate
(flush to pushbar)
Pushbar
Remove anti-rattle clip
1
Measure amount to cut off device.
Anti-rattle
clip
2
Minimum
499F STRIKE INSTALLATION
Prepare and install screws
through 2 strike slots.
1
3
4
#25 Drill
#10-24 tap
2 places
CL
Roller
(against door)
CL
Install strike hook and
additional strike screws.
2
Template aligns as shown.
3
1/16
Strike
hook
If using a mullion, holes
may be predrilled
CL
Template
(align on
C
and
against strike)
L
#25 Drill
#10-24 tap
2 places
#25 Drill
#10-24 tap
3 places
If 5/8 diameter wire access hole
has been predrilled in door, cut
device 5/16 from center of hole.
Note
5/16