Installation Instructions
IS6300-R05/10
Copyright © 2011 Ingersoll-Rand. All rights reserved.
6300 Surface Mounted Rim Strike
Important:
The New 6300
Electric Strike is never to be used as a door stop. Please install stops on frame
in appropriate locations. Ensure the exit device functions as intended for life safety concerns by verifying
electric strike and exit device compatibility. Maximum latch projection is essential to obtain full holding force.
When installed in a fail secure manner, the local Authority Having Jurisdiction shall be consulted with regard
to the use of selected panic hardware to ensure emergency exit from the secured area.
Catalog Specifications
Model
Mode
Voltage
Current
Duty
Amps
Ohms
6300
Fail Secure
12V
DC
Continuous
0.50
22
6300
Fail Secure
24V
DC
Continuous
0.24
89
Fail Locked = Fail Secure = FSE DC = Direct Current
Continuous Duty = Energized 1 minute or more
Dimensional Details
3/4"
(19.0mm)
1-5/8"
(42.0mm)
9"
(228.6mm)
8-1/4"
(209.6mm)
1-3/4"
(44.5mm)
5-1/2"
(139.7mm)
HORIZONTAL
ADJUSTMENT
MOUNTING
HOLES
LOCK DOWN
HOLES