Bringing Out of Storage
• Remove any covers from the engine, air filter
and exhaust pipe.
• Fill the engine with the correct quality and
viscosity oil into the engine, as necessary, refer
to
Technical Data, Lubrication System
. Install a
new oil filter if the filter was not changed during
conservation.
• Install new fuel filters and bleed the fuel system.
• Check the drive belt(s).
• Check the condition of all rubber hoses, and
retighten the hose clamps.
• Close the drain taps and install any drain plugs.
• Check the coolant level. Top up as necessary.
• Connect the fully charged batteries.
• Start the engine and warm it up at fast idle with
no load.
• Check that no oil, fuel or coolant leakage occurs.
• Fill the AdBlue/DEF tank. The solution must
fulfill ISO 22241 standards.
Conservation of the lubrication and fuel systems for more than 8 months’ stoppage:
• Drain the engine oil and fill up with
conservation
oil*
to just over the MIN marking on the dipstick.
• Connect the fuel suction and return hoses to a 1/3
full jerrican containing
conservation oil*
and 2/3
diesel fuel.
• Bleed the fuel system.
• Start the engine and run at a fast idle until about 2
liters (0.6 US gal) of the fluid in the jerrican have
been used. Stop the engine and re-connect the fuel
suction and return lines.
• Drain the conservation oil from the engine.
• Follow the other instructions on the previous page.
* Conservation oils are sold by oil companies.
Storage
88
47711296 01-2019 © AB VOLVO PENTA
Содержание TAD1340VE
Страница 1: ...Operator s manual 16L TP 6662 1 19d ...
Страница 102: ......
Страница 104: ......