Group 30 Electrical system
Checking B- diodes
1.
Connect the instruments positive probe to the di-
ode plate B- connection and the instruments neg-
ative probe to one of the stator windings connec-
tions (1-2-3).
2.
Read off the instrument as previously. A normal
value should be between 450 and 650 mV. Any
other value indicates a faulty diode.
3.
Then check the B- diodes in the opposite direction
by reversing the positive and negative probes.
Perform the same measurements as above. The
instrument should show a one “1” with these mea-
surements (furthest to the left). Any other value
on the instrument indicates a faulty diode. If any
of the diodes are faulty, the whole diode plate must
be replaced.
Checking D+ diodes
The diode plate’s three magnetization diodes are
checked in the same way as above.
1.
Connect the instrument’s positive probe to each
stator winding connection (1-2-3) and the negative
probe to D+. The voltage drop for each diode
should be between 450 and 650 mV.
2.
Then check the D+ diodes in the opposite direc-
tion by reversing the positive and negative
probes. Perform the same measurements as
above. The instrument should show a one “1” with
these measurements (furthest to the left). Any
other value on the instrument indicates a faulty di-
ode. If any of the diodes are faulty, the whole diode
plate must be replaced.