Voltronic Power SCC-MPPT 300W Скачать руководство пользователя страница 5

 

Fig. 9 

CAUTION: It may not cause any damage to solar module or unit when connecting 

polarity reversals. However, the unit will not be able to work normally.   

WARNING! Please use the appropriate cable. Please refer to Important Safety 

Warnings Section for the details.   

 

Step 4: Switch on DC breaker or install DC fuse 

After completing all wires, double check if all wires are connected well. Then switch 

on DC breaker or install DC fuse on. Take off the cover of solar module. When the 

voltage of solar module is 5VDC higher than battery voltage, the charger will 

automatically turn on to work. 

NOTE: If battery is not connected, even though solar module power is achieved, 

the charger is still not working. 

 

3.

 

Operation 

After all wires are connected, the solar charge controller will automatically be 

activated. At this time, the blue LED will light up and LCD display panel will show 

information. 

 

Switch Operation 

The switch has three modes during operation: 
Activate LCD backlight 

Press button for less than 1 second 

Select battery type* 

 

When the unit starts to work, press button for 1-3 

seconds to select battery type. 

DI

: vented battery 

D2

: sealed lead acid battery 

D3

: Gel battery 

D4

: NiCd battery 

D5

: Custom** 

Mute 

Press button > 3 seconds   

Power on 

Press button for 1 second to turn on the unit. 

*Please carefully to select battery type. It will damage battery if the setting is 

incorrect. Refer to charging voltage table in the appendix. 

**This option is self-defined bulk/floating voltage via bundled software.   

Status, LED/LCD Display and Audible Alarms 

 

 

Status 

LCD 

LED 

Alarm 

Polarity reversal on 

solar module 

connection. 

N/A 

Yellow LED on. 

N/A 

Polarity reversal on 

battery connection. 

N/A 

Red LED on. 

N/A 

Polarity reversal on 

battery and solar 

module connection. 

N/A 

Orange LED 

on. 

N/A 

Battery is in 

charging. 

 

Blue & Green 

LEDs on. 

N/A. 

Low battery 

voltage.* 

 

Flashing every 

sec. 

N/A 

Sounding every sec 

110% overload. 

 

Flashing 

every 2 secs. 

N/A 

Sounding every 2 secs. 

for 5 min. Then 

continuously sounding. 

*Refer to alarm point for low voltage table in appendix. 

Fault and error codes table: 

Status 

LCD 

LED 

Alarm 

Battery defect. There is power 

input from solar module, but 

battery voltage is too low.   

12V system: < 8.5V 

24V system: < 17V 

 

Green LED 

on. 

Continuously 

sounding. 

Overcharge and the charger will 

automatically cut off output. 

 

Blue LED on 

Continuously 

sounding. 

130% overload and the charger 

will automatically cut off output. 

 

N/A 

Continuously 

sounding. 

When solar input voltage is too 

high, the charger will 

automatically cut off charging. 

 

Blue LED 

flashes every 

second 

N/A 

 

Отзывы: