![Voltronic Power SCC-MPPT 300W Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/voltronic-power/scc-mppt-300w/scc-mppt-300w_quick-manual_1047790005.webp)
Fig. 9
CAUTION: It may not cause any damage to solar module or unit when connecting
polarity reversals. However, the unit will not be able to work normally.
WARNING! Please use the appropriate cable. Please refer to Important Safety
Warnings Section for the details.
Step 4: Switch on DC breaker or install DC fuse
After completing all wires, double check if all wires are connected well. Then switch
on DC breaker or install DC fuse on. Take off the cover of solar module. When the
voltage of solar module is 5VDC higher than battery voltage, the charger will
automatically turn on to work.
NOTE: If battery is not connected, even though solar module power is achieved,
the charger is still not working.
3.
Operation
After all wires are connected, the solar charge controller will automatically be
activated. At this time, the blue LED will light up and LCD display panel will show
information.
Switch Operation
The switch has three modes during operation:
Activate LCD backlight
Press button for less than 1 second
Select battery type*
When the unit starts to work, press button for 1-3
seconds to select battery type.
DI
: vented battery
D2
: sealed lead acid battery
D3
: Gel battery
D4
: NiCd battery
D5
: Custom**
Mute
Press button > 3 seconds
Power on
Press button for 1 second to turn on the unit.
*Please carefully to select battery type. It will damage battery if the setting is
incorrect. Refer to charging voltage table in the appendix.
**This option is self-defined bulk/floating voltage via bundled software.
Status, LED/LCD Display and Audible Alarms
Status
LCD
LED
Alarm
Polarity reversal on
solar module
connection.
N/A
Yellow LED on.
N/A
Polarity reversal on
battery connection.
N/A
Red LED on.
N/A
Polarity reversal on
battery and solar
module connection.
N/A
Orange LED
on.
N/A
Battery is in
charging.
Blue & Green
LEDs on.
N/A.
Low battery
voltage.*
Flashing every
sec.
N/A
Sounding every sec
110% overload.
Flashing
every 2 secs.
N/A
Sounding every 2 secs.
for 5 min. Then
continuously sounding.
*Refer to alarm point for low voltage table in appendix.
Fault and error codes table:
Status
LCD
LED
Alarm
Battery defect. There is power
input from solar module, but
battery voltage is too low.
12V system: < 8.5V
24V system: < 17V
Green LED
on.
Continuously
sounding.
Overcharge and the charger will
automatically cut off output.
Blue LED on
Continuously
sounding.
130% overload and the charger
will automatically cut off output.
N/A
Continuously
sounding.
When solar input voltage is too
high, the charger will
automatically cut off charging.
Blue LED
flashes every
second
N/A
7