Operation: Operating the generator
3.2.5
Stopping the generator
Gradually remove all loads from the generator before stopping the
generator engine.
To stop the engine:
■
On models with an electric starter, rotate the key to the off position.
■
On all diesel models, you must keep pressure on the stop lever until
the engine comes to a complete stop.
■
On diesel generators with an electric-start engine and auxiliary
recoil starter, if the generator does not have a battery, move the red
or black lever near the fuel tank to the down position.
■
On other models, move the start/stop switch on the engine to the
stop position.
Always wait for the engine to come to a complete stop.
Runaway diesel engine
If the diesel engine does not stop when the start/stop switch is
moved to the stop position, the oil in the engine sump has been
overfilled and the engine is using over-pressurized sump oil as fuel.
To stop the engine with this condition you must block the air intake
flow until the engine stops.
If this situation has occurred, the air filter will be saturated with oil
and must be replaced before restarting the engine.