background image

PIS20220511-RG

© Voltex Electrical 2022. All Rights Reserved.

Installation

 Technical specification

Fasten the flood light bracket to the mounting surface with stainless steel bolts or similar 
suitable mounting accessories
Adjust the flood light to direct the light output as required, then tighten the adjustment 
screws on each side of the flood light 
If hard-wiring the flood light, remove the 3-pin plug and connect the cable as follows:
∆Brown – Active/Live
∆Blue – Neutral
∆Yellow/Green – Earth
All hard-wiring connections must be protected by means of a suitable IP rated junction box 
or connector
Ensure the flex is installed to minimise tension at all connection points

1

2

3

4

5

Note: All fixed wiring must be carried out by a licensed electrician.

Light Source 

LED

Driver

Housed internally. Non-Dimmable

Colour Temperature 

Cool White (5700K), Warm white (3000K)

Beam Angle 

120°

Life Span 

>50,000 hours

IP Rating 

IP66

Housing Colour

Black

Glass Fascia

Tempered, semi-frosted

Working Temperature

 -20C to +50C

Connection Cable

2m flex and plug

Product Code

Power 

(W)

(mm)

(mm)

(mm)

Lumen output 

(lm)

Efficiency 

(lm/W)

Net weight 

(kg)

FLB-CW/16W
FLB-WW/16W

16

205

135

42

1600-1800

100-110

1.1

FLB-CW/24W
FLB-WW/24W

24

251

170

45

2400-2700

100-110

1.6

FLB-CW/50W

50

330

225

55

5000-5500

100-110

3.1

FLB-CW/72W

72

372

250

75

7000-7900

100-110

4.8

FLB-CW/120W

120

450

340

75

12000-13000

100-110

5.8

FLB-CW/200W

200

450

340

90

21000-22400

100-110

7.8

Отзывы: