background image

5. If solar module cannot provide current or the current is less than 1Amp for 5 minutes, the controller will 
switch to Night mode and display            in the lower right hand corner.   
 
 
6. When the unit is in the default display mode, Pressing the ‘

enter’

 button will turn the load ON or OFF 

manually. The                         

arrow/lamp symbol will be displayed when the load terminal is ON. 

 

 

 

 

FEATURES 

 

1. PWM Charge control 
 

Depending on the actual battery level, various charging procedures, float charging and boost 

charging are automatically performed. The final charging voltage (Float) is also temperature 

compensated. 

 
2. Deep discharging protection 

If the battery falls below a specified voltage (11.0V/22V), the load output is disconnected preventing 
excessive discharge of the battery. Once the voltage increases to 12.0V/24V the load will be 
automatically re-connected. The set points of the deep discharging protection are predefined and 
cannot be reset. 

3. Temperature Compensation 

ISC3020 has an internal ambient temperature sensor that compensates during the float mode.   

 

 

INSTALLATION 

 

 

Install the controller in a ventilated area away from flammable materials and gases.   

 

The surface should be solid, even, dry and nonflammable. 

 

The battery to controller cable should be as short as possible (1-2m) and be of a suitable diameter 
to minimize voltage loss.   

 

Do not assemble outdoor, the unit should be installed in the way to be protected against humidity, 
dripping, rainwater as well as direct and indirect heat (sunlight). 

 

To ensure the air circulation for cooling an area of 15cm on each side of the unit must be kept free. 

 

The LCD display should be protected against UV rays (e.g. sunlight). Long time exposure to UV 
rays can permanently discolor the LCD. 

 

The solar charge controller may only be connected to the local loads and the battery by trained 
personnel and in accordance with any applicable regulations. 

 

Follow the installation and operating instructions for all components of the PV system. 

 

Ensure that no cables are damaged. 

 

Ensure that polarity of Solar panel/battery/load is correct and use only insulated tools. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ISC3020

Страница 1: ...Installation and Operating Instructions Solar System Controller ISC3020 ...

Страница 2: ......

Страница 3: ...lar panel PV may be connected to the solar charge controller 3 Do not connect any defective or damaged measuring equipment 4 Follow the general and national safety and accident prevention regulation 5 Never alter or remove the factory plates and identification labels 6 Keep children away from PV Battery systems 7 Never open the device No user serviceable parts inside 8 One set solar module can con...

Страница 4: ...tor the state of charge of the battery Controls the charging process Control the connection disconnection of loads Make sure Solar system works at proper condition Features Load Terminal switches Positive side Manual load switch with automatic re start OPERATING THE CONTROLLER The display shows a variety of system data by symbols and digits Both buttons control all settings and display windows 1 D...

Страница 5: ...e default window will show like below battery voltage capacity volume of the battery 2 Press menu button once to check charging current 3 Press menu button again to display the load current 4 When the charging current or output current is less than 0 5Amp the LCD will always show Min A When there is no current it will show 0 Amp 4 ...

Страница 6: ...nsation ISC3020 has an internal ambient temperature sensor that compensates during the float mode INSTALLATION Install the controller in a ventilated area away from flammable materials and gases The surface should be solid even dry and nonflammable The battery to controller cable should be as short as possible 1 2m and be of a suitable diameter to minimize voltage loss Do not assemble outdoor the ...

Страница 7: ...from 6 to 1 according the above diagram Use with 12V or 24V battery bank controller will detect voltage of battery automatically Never exceed the nominal ratings see below technical data for reference Suggested cable length 10m solar panel connection cable 2m battery connection cable 5m load connection cable TECHNICAL INFORMATION Max Input Current 30A DC Max Input Voltage Voc 45V DC Max Load Curre...

Страница 8: ...rse current protection The following installation faults do not destroy the controller After correcting the fault the device will continue to operate correctly Overcharge protection Deep discharge protection Reverse polarity protection of load panel and battery Automatic electronic fuse Short circuit protection of load and panel Over voltage protection at panel input Open circuit protection withou...

Страница 9: ...rentiated whether there is a temporary malfunction e g regulator overload or a more serious system error that can be remedied by appropriate external measures Since not all errors can be simultaneously displayed the error with the highest error number priority is displayed If several errors are present the second error code is displayed after remedying the more significant error The following mean...

Страница 10: ...y removing all connections in Reverse sequence from 6 to 1 see Page 8 then follow the reset procedure i While holding down the Menu button re connect the Battery terminals to the unit ii Release the Menu button this will prompt the LCD to show FFFF iii First connect the PV then the Load terminals NOTE Always connect the Negative first then the Positive for all connections 5 Meaning Solar Module re...

Страница 11: ... disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice Specifications are subject to change without prior notice Copyright reserved by Electro Parts Australia Pty Ltd Instruction manual Ver 2 1 10 ...