Voltech BC-2415P Скачать руководство пользователя страница 6

G.  STORAGE 

 

 

If the RV/ etc. is in storage for an extended period of time and no solar panels are available to charge the battery, To help guard 

 

against Self-discharge of the Battery;   

 

• Leave the AC power connected & the Battery Charger turned on. 

 

• 

ENSURE ALL loads are turned OFF or Dis-connected from the Battery. 

 

 

The charger has an automatic Standby Charge Mode and a 21 day New Cycle charge to take care of the battery in storage.   

 

• Or disconnect the Battery charger from the battery if the AC Mains is to be disconnected or turned off.   

 

 

Warning; 

 

 

Batteries on charge should not be left unattended for extended periods. The charging process & battery condition should be 

 

checked regularly. 

 

H.  User Define Charging Profiles

(first install the HBC software & drivers onto your PC)

 

 

 

Connect the charger to the personal computer via the USB port (6) then you can set your own charging configuration. 

 

There are two positions allocated to store the user charge profiles.(Battery Selection Switch (4) position 8 or 9 ) 

 

Note; The Maximum time these two profiles can run is 99 hours. The output will then stop until charger is reset. 

 

 

I.  Equalization Charging for wet type battery only 

 

 

Warning:

 Explosion Hazard 

 

      Explosive gases from battery during equalization, extreme care must be exercised. 

 

 

 

Caution:

  Only flooded lead acid battery which must have had one complete charge cycle before equalization charge. 

 

      Make sure electrolyte level is sufficient. Disconnect all DC load connected to the battery 

             Exercise extreme care to comply with the above cautions when Auto-Equalization is selected. 

 

 

Wet lead acid batteries requires periodic higher voltage charging (about 10% over usual absorption voltage) to balance the 

 

Voltage  of each cell, reverse the high concentration of electrolyte at the bottom and clear up large sulfate crystals on the plates. 

 

You can  use the Equalization Selection Switch (8) to perform the manual equalization through optional remote display or Auto 

 

equalization by charger itself. 

 

Once Auto is selected, the charger will start Equalization automatically if charger stays in Float mode for over 21 days. 

 

After entering into this mode, the Absorption indicator (Amber LED) will flash & the Equalization will run for 240 minutes.   

 

The charger will then go back to Float once completed. 

 

 

Remark:  1. This mode only can be operated at WET (Flooded) selection (Battery Selection Switch (4) set to position 1) 

 

 

2. Any time during this mode, Pressing the FUNC button on the optional remote display(HBR-3100) for 5 seconds         

will force the Equalization mode to end and the charger to re-enter Float mode. 

 

 

3. Take special precautions as battery will emit explosive gas during equalization charge. 

 

J.  Dual bank charging 

 

 

This feature is for applications where there are two totally separate batteries. 

The two batteries must be of the same type (chemical makeup) & capacity to avoid over and under charging because you can 

only select one battery type charging profile for both banks. 

The two banks are charged simultaneously and the battery with the lowest level (lower resistance)gets most share of the current 

in the Bulk stage until it catches up to the same voltage level as the second battery (battery with higher initial level).   

 

Both batteries will go to the Absorption and the Float Charge at the same time. 

 

K.  Temperature Sensor   

 

 

Warning: 

 

The temperature sensor must be installed at the Negative Terminal of the 

 

battery terminal, In-correctly connecting to the Positive   Terminal will 

 

damage the charger and the sensor. 

 

The temperature sensor (accessory) is used for optimal charging over a wide 

 

ambient temperature range. 

 

The Temperature sensor should be positioned so as not to be affected by any 

 

other cooling or heating source. 

 

Plug in the temperature sensor 

before 

switching on the charger to activate 

 

the temperature control function, 

Never plug in the Sensor during 

 

charging.

 

 

Compensation voltage for this temperature sensor is 20mV/C, the higher the 

 

battery temperature, the lower the charging voltage. 

 

When battery temperature reaches 60°C, the charger will shut-down, Fault 

 

and OTP indicator will light up. 

Содержание BC-2415P

Страница 1: ...cause risk of fire electric shock or equipment damage Disconnect the mains supply before connecting or disconnecting the links to the battery If the charger does not work properly or if it has been damaged unplug its AC and DC connection Do not use this charger in connection with any medical device or life support system This appliance is not intended for use by persons including children with red...

Страница 2: ...el AGM LiFePO4 Calcium Calcium and now also Lead Crystal batteries There are also two User programmable charging profiles for the professional users via the USB port by personal computer In addition the programmed maintenance charge provides a timely Equalization charge for the Wet lead acid battery Almost all the protections are controlled by the Micro Processor On start up the charger runs a ser...

Страница 3: ...minal s 10 Ventilation Fan 11 Inlet AC socket with Mains fuse holder 12 Temperature Sensor Socket Connection to Battery Temperature sensor accessory Sensor to increase decrease charging voltage at low high battery temperature B Using the charger 1 Check the supplied accessories AC cord Remote Battery temperature sensor CD software USB cable are with the package 2 Remove the magnetic dummy remote c...

Страница 4: ...he operation of connected powered appliance or connections E Battery Charger Installation and Connection Observe the warnings safety precautions before rushing to install and operate the charger Check battery condition fill up cells for wet battery clean battery poles Secure the battery charger in a well ventilated place make sure the mounting surface is flat and without soft covering material or ...

Страница 5: ...orption stage Charging current will now decrease gradually until a pre set value at which the charger then automatically switches to Float Stage The max Absorption time is also controlled by the time in Bulk charge and battery type selected Stage 3 THE UO PHASE FLOAT mode Constant voltage charging Float LED is ON In Float stage the battery is full and only takes in the amount of current necessary ...

Страница 6: ...to equalization by charger itself Once Auto is selected the charger will start Equalization automatically if charger stays in Float mode for over 21 days After entering into this mode the Absorption indicator Amber LED will flash the Equalization will run for 240 minutes The charger will then go back to Float once completed Remark 1 This mode only can be operated at WET Flooded selection Battery S...

Страница 7: ...mote temp sensor at 60 C Flashing Solid ON OFF Manual power on off reset after fault cleared Alarm flash Buzzer on Bat Over Temp Fan not working or stuck Flashing Flashing OFF Manual power on off reset after fault cleared Alarm flash Buzzer on Fan Fault Output Over Voltage Protection when output voltage is 4 higher than it should be for the battery type and charge stage Solid ON OFF OFF Manual pow...

Страница 8: ...oad and charger not balanced Battery does not get full charge All indicator LED work normally and sequentially OTP LED flashing Bad battery connection Battery type select switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for loose contact right cable size cable integrity Recheck batter...

Страница 9: ...ad 230V 2 5A 3 5A 5 0A Protection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically if Fault Condition is Removed within 20 seconds Otherwise the charger will shut down until re start the charger again Reverse Polarity Automotive type Blad...

Страница 10: ...r level set type of fault with alarm etc and can remote control the output terminal On OFF trigger the Equalization charging for wet battery and force charger to float mode It can be mounted on BC charger by replacing the dummy cover on the front panel or remotely mounted with 10m extension cable going through the unplugged hole at the front of the dummy panel II Connection 1 10 Meters Phone Cable...

Страница 11: ...r output ON and OFF Green LED is illuminated when output is ON 2 Alarm Can be silenced or audible by toggling this button default is audible Red LED will illuminate when fault occurred 3 Func To toggle charger setting Menu and select scrolling to make display continue to scroll all setting See optional remote programming section 4 Set To confirm the chosen feature you selected ...

Страница 12: ...e Version Displays the current control software version Remote Short cut 1 Press and hold the SET button for 5 seconds and release the button to enter Equalization mode Equalization selection slide switch on main unit should be selected at manual position 2 Press and hold the Func button for 5 seconds and release the button to force the charger to Float mode V Fault Indication 1 Charger High Temp ...