c) Select program
• Hold down the MODE button for 2 seconds to set the program for all four charge slots.
• Press the MODE button to change the program.
• If you want to change the program for a particular charger compartment, press the SLOT
button until the appropriate display flashes. Then select the program with the MODE button.
• By changing the program you may also change the charging current.
d) Select charging current
• The default factory setting is a charging current of 75 mA.
• After you make connection to the power supply or insert a battery, press the CURRENT button
within 6 seconds to change the charging current for all occupied charger compartments.
• After confirming the setting, you cannot adjust the value for the time being. If you want to
adjust the charging current, select the program again or remove the batteries and put them
back in.
• The discharge current is automatically adjusted according to the selected charging current.
9. Programs
a) Charging (CHARGE)
• This program is used for charging rechargeable batteries.
• The rechargeable battery is being charged to its full capacity.
• The capacity in "mAh" appears on the display.
b) Discharging (DISCHARGE)
• This program is used to reduce the so-called memory effect of rechargeable batteries.
• The rechargeable battery is discharged to a voltage of 6.3 V.
• Once the process is finished, the discharged capacity in "mAh" is displayed.
• After the program, the device does not switch to trickle charging.
22