VOLTCRAFT MS-100 Скачать руководство пользователя страница 2

 OPERATING INSTRUCTIONS

Version 12/10

MS-100 VOLTAGE TESTER 

Item No. 12 30 66

INTENDED USE

1. 

The product is intended for direct or indirect testing of voltage from 12 – 250 V/AC or 12 V/DC . A display shows 
the voltage value. Use only in dry indoor environments.

This product fulfils European and national requirements related to electromagnetic compatibility (EMC). 
CE conformity has been verified and the relevant statements and documents have been deposited at 
the manufacturer.

For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you use the product 
for purposes other than those described above, the product may be damaged. In addition, improper use can 

cause hazards such as short circuiting, fire, electric shock etc. Read the instructions carefully and keep them. 

Make this product available to third parties only together with its operating instructions.

DELIVERy CONTENT

2. 

Voltage detector

• 

Plastic cap

• 

Operating instructions

• 

SAFETy INSTRUCTIONS

3. 

Read the operating instructions carefully and especially observe the safety information. 
If you do not follow the safety instructions and information on proper handling in this 
manual, we assume no liability for any resulting personal injury or damage to property. 
Such cases will invalidate the warranty/guarantee.

Persons / Product

The device is not a toy. Keep it out of the reach of children and pets.

• 

Do not leave packaging material lying around carelessly. These may become dangerous playing material 

• 

for children.
Protect  the  product  from  extreme  temperatures,  direct  sunlight,  strong  jolts,  high  humidity,  moisture, 

• 

flammable gases, vapours and solvents.

Do not place the product under any mechanical stress.

• 

If it is no longer possible to operate the product safely, take it out of operation and protect it from any 

• 

accidental use. Safe operation can no longer be guaranteed if the product:

is visibly damaged, 

 -

is no longer working properly, 

 -

has been stored for extended periods in poor ambient conditions or 

 -

has been subjected to any serious transport-related stresses.

 -

Please  handle  the  product  carefully.  Jolts,  impacts  or  a  fall  even  from  a  low  height  can  damage  the 

• 

product.
Also  observe  the  safety  and  operating  instructions  of  any  other  devices  which  are  connected  to  the 

• 

product.
In  schools,  training  facilities,  hobby  or  self-service  workshops,  handling  of  electrical  devices  must  be 

• 

monitored by trained personnel.
When  operating  on  commercial  premises,  the  relevant  accident  prevention  regulations  of  workers’ 

• 

compensation boards for electrical equipment must be observed.
When working with power supplies or chargers, do not wear any metallic or conductive chains, bracelets, 

• 

rings etc. Never connect the power supply or charger with humans or animals.

Miscellaneous

Consult an expert when in doubt about operation, safety or connection of the device.

• 

Maintenance,  modifications  and  repairs  are  to  be  performed  exclusively  by  an  expert  or  at  a  qualified 

• 

shop.
If  you  have  queries  about  handling  the  device,  that  are  not  answered  in  this  operating  instruction,  our 

• 

technical  support  is  available  under  the  following  address  and  telephone  number:  Voltcraft

®

,  92242 

Hirschau, Lindenweg 15, Germany, phone 0180 / 586 582 7

OPERATION

4. 

Remove the plastic cap before use.

1. 

Replace it when the tester is not being used.

2. 

Direct measurement of AC voltage

Put one finger on the contact point “Direct Test”.

1. 

Touch the test point with the metal tip of the voltage tester.

2. 

A lightning symbol and some numbers appear on the screen if there is voltage. The numbers are separated 

3. 

into five groups by the symbol “V”. The five groups are : 12 , 36 , 55 , 110  and 230 V respectively. The last 

group of numbers appears on the display is the approximate measurement value. 

The measured voltage is 230 V.

Direct measurement of DC voltage

Put one finger on the contact point “Direct Test” and put another finger on the negative pole of the tested 

1. 

object. (Or vice versa).

Touch the positive pole of the tested object with the metal tip of the voltage tester.

2. 

A lightning symbol and some numbers appear on the screen if there is voltage. The numbers are separated 

3. 

into five groups by the symbol “V”. The five groups are : 12,  36, 55, 110 and 230 V respectively. The last 

group of numbers to appear on the display is the approximate measurement value. 

Indirect measurement of AC voltage

Do not touch the exposed wire. Only touch the cable with proper insulation.

Put one finger on the  contact point “Inductance, Break-point Test”

1. 

Place the metal tip of the tester close to the cable where you would like to test.

2. 

To give better performance, split the parallel lines or press the measured line with your hand to eliminate 

3. 

interference.
A lightning symbol and some numbers appear on the screen if there is voltage. There will be no sign on the 

4. 

screen if there is no voltage.

DISPOSAL

5. 

In order to preserve, protect and improve the quality of environment, protect human health and 
utilise natural resources prudently and rationally, the user should return unserviceable product to 
relevant facilities in accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately and not as 
municipal waste.

TECHNICAL DATA

6. 

Testing range:

12 - 250 V/AC, 12 V/DC

Display:

12, 36, 55, 110, 230 V

Dimensions (W x H x D): 132 x 19 x 16 mm
Weight:

20 g

These operating instructions are published by Voltcraft®, 
Lindenweg 15, D-92242 Hirschau/ Germany, Phone +49 180 586 582 7.

All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the 

capture in electronic data processing systems require the prior written approval by the editor. Reprinting, 
also in part, is prohibited. 

The operating instructions reflect the current technical specifications at time of print. 
We reserve the right to change the technical or physical specifications.
© Copyright 2010 by Voltcraft®.

V1_1210_02-HL

Содержание MS-100

Страница 1: ...tsweise die Sicherheit oder den Anschluss des Produktes haben Lassen Sie Wartungs Anpassungs und Reparaturarbeiten ausschließlich von einem Fachmann bzw einer Fachwerkstatt durchführen Sollten Sie noch Fragen zum Umgang mit dem Gerät haben die in dieser Bedienungsanleitung nicht beantwortet werden steht Ihnen unser Technischer Support unter folgender Anschrift und Telefonnummer zur Verfügung Voltc...

Страница 2: ...enance modifications and repairs are to be performed exclusively by an expert or at a qualified shop If you have queries about handling the device that are not answered in this operating instruction our technical support is available under the following address and telephone number Voltcraft 92242 Hirschau Lindenweg 15 Germany phone 0180 586 582 7 OPERATIon 4 Remove the plastic cap before use 1 Re...

Страница 3: ...es concernant le mode de fonctionnement la sécurité ou le raccordement de l appareil Tout entretien ajustement ou réparation ne doit être effectué que par un spécialiste ou un atelier spécialisé L appareil de mesure pour lesquelles vous ne trouvez pas de réponses dans le présent mode d emploi nos support technique se tient volontiers à votre disposition à l adresse et au numéro de téléphone suivan...

Страница 4: ...aansluiten van het apparaat Onderhoud aanpassingen en reparaties mogen alleen uitgevoerd worden door een expert of in een daartoe bevoegde winkel Voor vragen over het omgaan met het product die niet beantwoord worden in deze gebruiksaanwijzing is onze afdeling technische ondersteuning bereikbaar op het volgende adres en telefoonnummer Voltcraft 92242 Hirschau Lindenweg 15 Duitsland telefoon 0180 5...

Отзывы: