background image

a) Line current measurement

1. 

Connect the plug to a 230V AC mains socket.

2.  Connect the main cable of the load to the socket plug.
3.  Put the clamp around the 

AX1

 or 

AX10

 rings and switch the load on

4. 

Read the value of line current in the 

AX1

 ring or divide by 10 the value of current read in 

the 

AX10

 ring.

b) Voltage and power measurement

The ground wire (PE) is used as protection wire.
Measure the voltage difference between N and PE to check whether the grounding is in good 

condition or not.

1. 

Connect the plug to a 230V AC mains socket.

2.  Connect the main cable of the load to the socket plug.
3.  Put a power clamp around the 

AX1

 ring and the clamp’s test leads in the V inputs of the 

instrument then switch the load power on.

4. 

Read the correspondent values of current, voltage and absorbed power of the connected 

load.

Care and cleaning

•  Apart from the occasional cleaning the adapter is maintenance free.
•  Disconnect the product from the mains before each cleaning.
•  Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as 

they can cause damage to the housing and malfunctioning.

• 

Clean the product with a dry, fibre-free cloth.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the house-

hold waste. At the end of its service life, dispose of the product in accordance with 

applicable regulatory guidelines.

 

You thus fulfill your statutory obligations and contribute to the protection of the envi

-

ronment.

Technical data

Nominal voltage ............................

max. 250 V/AC, 50/60 Hz

Nominal current ............................

max. 16 A 

Protection type ..............................

IP40

Operating temperature .................

0 to +40 °C

Operating humidity .......................

 max. 80 % up to 31°C

 

decreasing linearly to 50 % at 40°C

Storage temperature .....................

-20 to +60 °C

Storage humidity ...........................

<80 % RH (non condensing)

Altitude ..........................................

max. 2100 m

Overvoltage category ...................

CAT III 300 V

Dimensions (L x W x H)

 ................

225 x 68 x 58 mm

Weight

 ..........................................

approx. 252 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in

-

cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represent the technical status at the time of printing.

Copyright 2021 by Conrad Electronic SE. 

  

 