42
CYC-CYCLE
= charge - discharge - charge
ALV-ALIVE
= charge - discharge - charge - discharge - charge
WIN-WINTER
= discharge - charge - pause - discharge - charge - pause...
PSH-PUSH
= charging for 1 minute with very high current
Each entry, e.g. like the program selected here, can be cancelled with the ESC
button.
Now, the discharge mode is to be defined. Two discharge options are available.
automatic or manual.
As in the CHARGE and the PUSH program the accumulator is only charged, this
menu point is skipped in the CHARGE and PUSH program and the charge program
starts immediately.
"DIS-MODE "
"1. AUTOMATIC "
"2. MANUAL Umin "
The discharge current is always automatically adjusted to the capacity of the accu-
mulator and cannot be adjusted. Only the final discharge voltage can be set in dis-
charge mode.
In automatic discharge mode, the programs Cycle, Alive and Winter leave approx.
70% of the capacity in the accumulator. In the test program CHECK, the residual
capacity is approx. 50%.
In manual discharge mode, the discharge current can be set from 1.75 to 2.00V in
50mV steps.
"DIS-VOLTAGE "
" 1.75V "
In the WINTER programme it is necessary to determine the pause period to be main-
tained between the cycles. It can be set from 3 to 30 days; a pause of 7 days is rec-
ommended.
"BREAK "
" 7 DAYS BREAK "
Now the programme starts.
CAUTION!
If any parameter was entered wrong, the program must be stopped imme-
diately!
Due to the very high charge and discharge current of this device, it is not
recommended to simply disconnect the accumulator (sparking)!
Содержание CT-1500Pb
Страница 95: ...95...