b) Persons and product

• 

People who set up, use and service the product must have sufficient knowledge 

about the measuring process and the meaning of the measurements. This do-

cument provides valuable information on these topics. The instructions in this 

document must be understood, observed and followed. To ensure that no risks 

result from the interpretation of the measurements, the user must have specialist 

knowledge – the user shall be liable for all damage/risks caused by incorrectly 

interpreting the measurements due to insufficient knowledge.

•  In schools, educational facilities, hobby and DIY workshops, the product must be 

operated under the supervision of qualified personnel.

•  Always comply with the accident prevention regulations for electrical equipment 

when using the product in commercial facilities.

c) Batteries

•  Ensure that the batteries are inserted in the correct polarity.
•  To prevent battery leakage, remove the batteries if you do not plan to use the 

product for an extended period. Leaking or damaged batteries may cause acid 

burns if they come into contact with your skin. Always use protective gloves when 

handling damaged batteries.

•  Keep batteries out of the reach of children. Do not leave batteries lying around, as 

they constitute a choking hazard for children and pets.

•  Replace all of the batteries at the same time. Mixing old and new batteries can 

cause the batteries to leak and damage the product.

• 

Batteries must not be dismantled, short-circuited or thrown into fire. Never rechar

-

ge non-rechargeable batteries. This may cause an explosion!

Product overview

a) Meter

1

2

3

4

5

6

7

8

11

12

10

9

1  Measurement probe (replaceable)
2  Protective cap
3  Screw cap

 button

 button

6  LCD display
7  Battery compartment cover
8  Eyelet (for the carry strap with ring)

 button

10 Electrolyte container
11 Probe tip (electrode)
12 Probe cap

b) LCD display

D

F

H

I

J

K

E

A

C

G

B

 MIN 

symbol

B  Battery status indicator

 MAX 

symbol

D  Operating modes
E  Measured value
F  Units

CAL 

calibration symbol

H  Measured temperature value
I  Temperature unit (

°C

 or 

°F

)

J  Automatic temperature compensation
K  Data hold symbol (

 HOLD

)

Setup

a) Inserting/replacing the batteries

•  Use the hex key to loosen the screws on the battery compartment cover 

(7)

 on the top of 

the meter, and then remove the battery compartment cover.

•  Insert the four 1.5 V AAA batteries (included) into the battery compartment, ensuring that 

they are inserted in the correct polarity (observe plus/+ and minus/- markings). The polarity 

is indicated in the battery compartment. The two batteries on each side must be inserted 

in the same polarity.

•  Replace the battery compartment cover and screw it back into place. Ensure that sealing 

ring in the battery compartment cover is in the correct position.

• 

The batteries must be replaced when the display contrast drops significantly, when the 

device does not switch on, or when the battery status indicator 

(B)

 on the LCD display 

(6)

 

indicates a low battery.

•  If this occurs, replace the batteries. To change the batteries, follow the steps above, ensu-

ring that you remove the old batteries before inserting the new batteries.

 Operating instructions

KBM-80 Combined measuring unit

Item no. 1763396

Intended use

This product is designed to measure the pH value, redox potential (ORP) and temperature of 

water and aqueous solutions using replaceable measuring probes. Typical applications include 

drinking water, waste water, surface water, swimming pools, fish farms and process chemistry. 

The pH value provides information about the content of hydrogen ions in a liquid. The redox 

value is measured and displayed in mV. The temperature can be measured in °C and °F. The 

measurements provide important information for drinking water treatment, water monitoring 

and in industry and laboratories. The product is powered by four 1.5 V AAA batteries.
For safety and approval purposes, do not rebuild and/or modify this product. Using the product 

for purposes other than those described above may damage the product. In addition, improper 

use can cause hazards such as a short circuit or fire. Read the instructions carefully and store 

them in a safe place. Only make this product available to third parties together with its operating 

instructions.
This product complies with statutory, national and European regulations. All company and pro-

duct names contained herein are trademarks of their respective owners. All rights reserved.

Package contents

•  Meter with measuring 

probe

•  3 x 50 ml buffer solution 

(pH 4, 7 & 10)

•  1 x electrolyte solution
•  Carry strap with ring
•  Hex key
•  2 x replacement screws

•  Storage case
•  4 x 1.5 V AAA batteries
•  Operating instructions

Up-to-date operating instructions  

To download the latest operating instructions, visit www.conrad.com/down-

loads or scan the QR code on this page. Follow the instructions on the web-

site.

Explanation of symbols

  The symbol with an exclamation mark in a triangle is used to highlight important 

information in these operating instructions. Always read this information carefully.

  The arrow symbol indicates special information and tips on how to use the product.

Safety information

Read the operating instructions and safety information carefully. If you do not 

follow the safety information and information on proper handling in these ope-

rating instructions, we will assume no liability for any resulting personal inju-

ry or damage to property. Such cases will invalidate the warranty/guarantee.

a) General information

•  The device is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. It may become a dange-

rous plaything for children.

• 

Protect the product from extreme temperatures, direct sunlight, strong jolts, flam

-

mable gases, vapours and solvents.

•  Do not place the product under any mechanical stress.
•  If it is no longer possible to operate the product safely, stop using it and prevent 

unauthorised use. Safe operation can no longer be guaranteed if the product:

 - is visibly damaged, 
 - is no longer working properly, 
 - has been stored for extended periods in poor ambient conditions or 
 - has been subjected to any serious transport-related stress.

•  Handle the product carefully. Jolts, impacts or a fall even from a low height may 

damage the product.

•  Consult a technician if you are not sure how to use or connect the product, or if 

you have concerns about safety.

• 

Maintenance, modifications and repairs must be carried out by a technician or a 

specialist repair centre.

•  If you have any questions which are not answered in these operating instructions, 

contact our technical support service or other technical personnel.

Содержание 1763396

Страница 1: ...es ph Werts Redox Potentials ORP sowie der Tempe ratur unter Verwendung wechselbarer Mess Sonden in Wasser und w ssrigen Medien aus gelegt Anwendungsbeispiele hierf r sind z B Trinkwasser Abwasser Obe...

Страница 2: ...rt nur die Werte der letzten 2 Kalibrierungspunkte 7 und 4 oder 7 und 10 Die Steilheit der Elektrode wird dementsprechend nur aus diesen zwei Werten berechnet 14 Nach der Kalibrierung mit pH 4 oder pH...

Страница 3: ...n Hausm ll ist untersagt Schadstoffhaltige Batterien sind mit dem nebenstehenden Symbol gekennzeichnet das auf das Verbot der Entsorgung ber den Hausm ll hinweist Die Bezeichnun gen f r das ausschlagg...

Страница 4: ...use This product is designed to measure the pH value redox potential ORP and temperature of water and aqueous solutions using replaceable measuring probes Typical applications include drinking water...

Страница 5: ...ensures precise measurements when there are different liquid temperatures Measuring the pH value 1 Rinse the probe tip 11 with clean water and wipe it dry 2 Press the button 4 to switch on the meter 3...

Страница 6: ...Technical data Power supply 4 x 1 5 V AAA batteries Operating current 5 mA Standby 5 A Battery life Approx 120 hours Low battery level indicator At 4 V residual voltage pH measurements Measurement ran...

Страница 7: ...Les exemples d applications de ce produit incluent eau potable eaux us es eaux superficielles piscines pisciculture et processus chimiques La valeur du pH vous renseigne sur la teneur en ions hydrog n...

Страница 8: ...choue le symbole SA ne s affiche pas 13 Pour d terminer la pente du c t des bases lorsque voulez mesurer une solution basique vous pouvez galement utiliser la solution tampon avec la valeur de pH 10 p...

Страница 9: ...ez les s par ment du produit b Piles Le consommateur final est l galement tenu de recycler toutes les piles ordonnance relative l limination des piles usag es il est interdit de les jeter avec les ord...

Страница 10: ...ORP en de temperatuur met gebruik verwisselbare meetsondes in water en waterachtige stoffen Toepassingsvoorbe elden zijn bijvoorbeeld metingen bij drinkwater afvalwater oppervlaktewater in een zwembad...

Страница 11: ...nder 70 of meer dan 130 ligt dan moet de meetsonde door een nieuwe worden vervangen Een waarde van 100 is echter ideaal Lees voor meer informatie over en stappen voor het vervangen van de meetsonde de...

Страница 12: ...en afgevoerd De aanduidingen voor irriterend werkende zware metalen zijn Cd cadmium Hg kwik Pb lood de aanduiding staat op de batterijen bijv onder de links afgebeelde vuilnisbaksym bool U kunt verbru...

Отзывы: