w w w . v o l t l i g h t i n g . c o m
VOLT
®
Stratum 9” & 12” Path & Area Light
VPL-300 Series
INSTALLATION INSTRUCTIONS
Wire Connections
6
Pigtail
Main Low Voltage
Supply Cable
Maintenance – Install/Replace Lamp
Please reverse Step 2 - Step 4 to expose the lamp and replace it with
correct wattage and type marked on the luminaire label. Reinstall the inner
shield and shade.
IMPORTANT: Halogen lamps must be protected from moisture and dust at all
times. Always reinstall the shade and lens when moved.
Strip both of the leads from the luminaire pigtail. Using two wire
connectors (sold separately), connect the leads from the luminaire to
the main low voltage supply cable leads.
Wire Connectors