[email protected] (58) 341-05-06 | [email protected] (58) 341-38-80 | [email protected] (22) 100-42-99
Other adapter include:
Initialization and Adaption
1)
Once the battery installed, the radiator display
INIL
, which means initialization.
2)
Install the radiator onto your radiator.
3
)
Then the radiator displays
AdAP
, then press
UP
button
(
change 0 to 1), which means the radiator will
adapt itself to the stroke of your valve body. To do this, the radiator will now be opened and closed twice to
store the end points.
Mode setting
Press
M
button to choose Manual mode/Away mode/PRG mode.
Clock & Weekday setting
Press and hold
P
button for 5s, set the clock (Min-Hour-Weekday) by pressing
UP
and
DOWN
button, each press of
P
button will go to next item setting.
7 days programmable setting
After finish the clock setting, press P to go to PRG schedule setting.
Set the schedule (Weekday-Period-Start time-Temp.) by pressing
UP
and
DOWN
button, each press
of
P
button will go to next item setting.
Default Setting:
Period
1
2
3
4
Time
Temp Time
Temp Time
Temp Time
Temp
12345(Mon~Fri.)
7:00
22
℃
8:30
19
℃
17:00 22
℃
22:00 19
℃
6(Sat.)
8:00
22
℃
8:30
22
℃
17:00 22
℃
22:00 19
℃
7(Sun.)
8:00
22
℃
8:30
22
℃
17:00 22
℃
22:00 19
℃